HomeMy WebLinkAbout162938 .-1.JMuy,r�ur,uo4 v,r-V'&-1 City of'Glendale Building Safety Department 5850 West Glendale Avenuc Glendale,Arizona 85301-2599 2nd Floor Re: Final inspection Report Permit M 162938 Project; Lifestyle Homes LLC Thvalo Cotton Lane-7715 N.cotton lane -Lot 166 hi accordance with the project plaits and specifications, the final report on the subject project is submitted. The post-tensioning cables Dave been installed and tensioned per plans and specifications. All inspected work indicates substantial compliance with the structural engineer's recoinmendations, approved drawings and/or revisions and project specifications. If you should have any further questions,please do not hesitate to call. Sincerely, PHOENIX TESTING&INSPECTION L.L.C. ` '� �- r �o,�son iF�ti 1C:1jj `: rti��liv Reviewed By. 8K2024 Robert N.Pocano,P.E. Principal Engineer FOR INSPECTION AND TESTING ONLY,NO DESIGN RESPONSIBILITY EXPRESSED OR RVIPLIED Home Energy Rating Certificate Rating Date: 10/24/2024 Final Report Registry ID: 574114706 Ekotrope ID: dNBe9V8d ■ v Index Score: Savings home'sur ■ r . -rformance -score.The lower the numb LitchfieldYo Park, + 85340 the more energy efficient . $ 673 Builder: - 5 learn more, visit www.hestndex.com Melative to HERS Reference . HomesA Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtul Annual Cost criteria of the following: Heating 1.8 $60 ENERGY STAR v3.1 Cooling 12.3 $422 ENERGY STAR v3 Hot Water 4.8 $161 2018 International Energy Conservation Code Lights/Appliances 11.1 $375 Service Charges $149 Generation (e.g.Solar) 0.0 $0 Total: 30.0 $1,165 HERSIndex Home Feature summary: Rating Completed by: .40,, ftfttW y Home Type: Duplex,single unit in Model: Plan 2 Energy Rater: Derek Flick ExistirrR :w Community: Tavalo Cotton Lane RESNET ID: 4514441 H01"eS 130 Conditioned Floor Area: 969 ft= Rating Company: JKP Energy Inspections,LLC 1D Number of Bedrooms: 2 1410 W.Guadalupe Rd.Ste 124 Gilbert,AZ 85233 Reffmixe iO Primary Heating System: Air Source Heat Pump•Electric•8.2 HSPF 480-350-9274 H&m i�0o Primary Cooling System: Air Source Heat Pump•Electric•14 SEER m Primary Water Heating: Residential Water Heater-Electric•0.92 Energy Factor Rating Provider: JKP Energy Inspections,LLC ro House Tightness: 5 ACH50(Adjusted Infiltration:4.86 ACH50) 1410 W.Guadalupe Rd.Ste 124 Gilbert,AZ 85233 480-350-9274 �•..._ 60 Ventilation: 32.2 CFM•11.27 Watts(Default)•Supply Only a 30_6 Duct Leakage to Outside: 38.76 CFM @ 25Pa(4/100 ft) ::This *�1 ;0H0"u Above Grade Walls: R-17 3e Ceiling: Vaulted Roof,R-2220 i 10 WindowType: U-Value:0.3,SHGC-0.25 0 0 Foundation Walls: N/A Framed Floor: N/A Derek Flick,Certified Energy Rater Digitally signed:10/24/24at 12:33 PM ek • • ,.. ■ The Energy Rating Disclosure for thk.horne is available from the Approved .. 7715 N Cotton Ln Unit 161 Litchfield Park,AZ 85340 Builder:Lifestyle Homes AZ Model:Plan 2 CommunLtC.Tavalo Cotton Lane THIS HOME IS CERTIFIED TO MEETTHE 2018 INTERNATIONALCONSERVATION i Building Features Ceiling Vaulted Roof,R-22 Duct Supply R-6.0,Return R-6.0 Above Grade Walls R-17 Dud Leakage to Outside 38.76 CFM @ 25Pa(4/100 ft2) Foundation Walls N/A Total Duct Leakage 38.76 CFM @ 25Pa(Rough-In,with Air Handler) Framed Floor N/A Heating Air Source Heat Pump Electric•8.2 HSPF Slab R-0.0 Perimeter,R-0.0 Under Cooling Air Source Heat Pump•Electric•14 SEER Infiltration 5 ACH50 Water Heating Residential Water Heater•Electric•0.92 Energy Window U-Value:0.3,SHGC:0.25 Factor Asa 3rd party extension of the code jurisdiction utilizing these reports,I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy conservation Code based on MARICOPA County.If rating is Projected,I certify that the building design described herein is consistent with the building plans, specifications,and other calculations submitted with the permit application.if rating is Confirmed,I certify that the address referenced above has pr$i /tested an at the mandatory provisions ofthe IECC have been installed to meet or exceed the intent o€the IECC orwill be verified as such by another party. Name: Derek Flick Signature: Organization: JKP Energy Inspections,LLC Digitally signed: 10/24/24 at 12:33 PM Ekotrope RATER-Version 4.2.1.3507 2018 IECCcompliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNETAccredtted HERS Rating Tool.All results are based on data entered by Ekotrope users. Ekotrope disclaims all Ilabilityfor the information shown on this report.