HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
1156 5023 W Peoria Ave (Lot 1156), Glendale, AZ 85302
by PREFERRED APARTMENT BUILDERS
exceeds the minimum requirements for the 2018 International Energy Conservation Code
Ceiling Flat: NA
Sealed Attic: NA
Vaulted Ceiling: R-22.5
Above Grade Walls: R-13.0
Foundation Walls: NA
Exposed Floor- NA
Slab: R-0.0 Edge, R-0.0 Under
Building Features
Duct: R-4.2
Duct Leakage to Outside: 0.035 CFM25 / CFA
Total Duct Leakage: 0.067 CFM25 / CFA
Infiltration: Htg: 3.70 Clg: 3.70 ACH @ 50 Pascals
Window: U-Value: 0.350, SHGC: 0.230
Air -Source HP: Electric, Htg: 7.5 HSPF2. Clg: 14.5 SEER2
Water Heating Conventional , Electric, 0.92 EF, 40.0 Gal
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application.
The proposed building has been designed to meet the 2018 IECC requirements in compliance with Chapter 4 based on Climate Zone 26 and with all mandatory requirements.
11 getall, signed by James SM
D t : 2024.10.21 11:14:12 EDT
Reason:
CN=James Styles, O=TOPBUILD HOME
SERVICES, INC., OU,
Name James Styles Signature EMAILADDRESS=james.styles@top.uild.wm,
C=US
Organization TOPBUILD HOME SERVICES, INC.
FAG~Build
HIM S.Vkes
Date 10/21 /2024
The 2018 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC).
No version of this software has been reviewed or approved by ICC or its affiliates.
Ekotrope HERS Rating Tool - Version 4.2.2
ENVIRONMENTS FOR
�,r�M°aro�°17h�+A
'sue: _,Na�1498-089,,��
788452EFL
HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
1157 5023 W Peoria Ave (Lot 1157), Glendale, AZ 85302
by PREFERRED APARTMENT BUILDERS
exceeds the minimum requirements for the 2018 International Energy Conservation Code
Ceiling Flat: NA
Sealed Attic: NA
Vaulted Ceiling: R-22.5
Above Grade Walls: R-13,0
Foundation Walls: NA
Exposed Floor: NA
Slab: R-0.0 Edge, R-0.0 Under
Building Features
Duct: R-4.2
Duct Leakage to Outside: 0.038 CFM25 / CFA
Total Duct Leakage: 0.078 CFM25 / CFA
Infiltration: Htg: 3.94 Clg: 3.94 ACH @ 50 Pascals
Window: U-Value: 0.350, SHGC: 0.230
Air -Source HP: Electric, Htg: 7.5 HSPF2. Clg: 14.5 SEER2
Water Heating: Conventional , Electric, 0.92 EF, 40.0 Gal
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application.
The proposed building has been designed to meet the 2018 IECC requirements in compliance with Chapter 4 based on Climate Zone 2B and with all mandatory requirements.
„ Digitally synod 6y James Srytes
Date: 2g2 .10.18 12:3g:15 EDT
Reason:
„1. CN=James Styles, O=TOPBUILD HOME
SERVICES, INC.. OU,
Name James Styles Signature EMAILADDRESS=james.styles@topbuild.c ,
r
c=us
Organization TOPBUILD HOME SERVICES, INC. Date 10/1812024
The 2018 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. { "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
Ekotrope HERS Rating Tool - Version 4.2.2 A� ' " •
,, s Ho. r4saoe�;
ENVIRONMENTS FOR a VDITATI
� - Est Build
�. Home Services 78M53EFL
Tru,
Branch Name:
Branch Address:
City/State/Zip:
Mesa Branch 394- Emc Insulation
7107 E Southern Ave Suite 107
Mesa, Az 85209
Installed Insulation Certificate
We certify that the insulation material listed here was installed at the address listed below:
Aluminum
Foam
Loose Fill
Kraft
Unfaced Foil
Open/Closed
BIBS®
R-Value
Attic
�
❑
R-22
Ceilings
❑
❑
❑ ❑
D
❑
Floors
0
El
❑
❑
❑
Walls
El
El
0 ❑
❑
❑
R-13
Basement
❑
El
❑ ❑
❑
❑
Crawlspace
❑
El
El ❑
❑
❑
Other
❑
El
0 ❑
❑
El
R-19
Contractor
(Signature)
Title
Sales/Estimation
Other than
loose fill 8
loose fill only aluminum foil only
aluminum foil
Initial Installed &
No.of Coverage
Minimum Settled Air Spaces Direction of
Thickness Pkgs Area (SF)
Thickness No Thickness Heat Flaw
6
Address or Lot Number: 5023 W Peoria
City, STZip: Glendale, AZ, Unit 1156/1157
Date Installed:
TT.OPS.FRM.010