Loading...
HomeMy WebLinkAbout161167n nov"i'og$ C a wN O n O Np N o�LyNjb miQp.0 m F G LE o r- O a a 0 o , CZ cd 6n fib Gn4-4 U O .� 0 rA O 0 c .N U Ul an cz Mu O U a� �.o 3 � � 0 0 40 V O O O a� 3 OU HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 1156 5023 W Peoria Ave (Lot 1156), Glendale, AZ 85302 by PREFERRED APARTMENT BUILDERS exceeds the minimum requirements for the 2018 International Energy Conservation Code Ceiling Flat: NA Sealed Attic: NA Vaulted Ceiling: R-22.5 Above Grade Walls: R-13.0 Foundation Walls: NA Exposed Floor- NA Slab: R-0.0 Edge, R-0.0 Under Building Features Duct: R-4.2 Duct Leakage to Outside: 0.035 CFM25 / CFA Total Duct Leakage: 0.067 CFM25 / CFA Infiltration: Htg: 3.70 Clg: 3.70 ACH @ 50 Pascals Window: U-Value: 0.350, SHGC: 0.230 Air -Source HP: Electric, Htg: 7.5 HSPF2. Clg: 14.5 SEER2 Water Heating Conventional , Electric, 0.92 EF, 40.0 Gal The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in compliance with Chapter 4 based on Climate Zone 26 and with all mandatory requirements. 11 getall, signed by James SM D t : 2024.10.21 11:14:12 EDT Reason: CN=James Styles, O=TOPBUILD HOME SERVICES, INC., OU, Name James Styles Signature EMAILADDRESS=james.styles@top.uild.wm, C=US Organization TOPBUILD HOME SERVICES, INC. FAG~Build HIM S.Vkes Date 10/21 /2024 The 2018 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC). No version of this software has been reviewed or approved by ICC or its affiliates. Ekotrope HERS Rating Tool - Version 4.2.2 ENVIRONMENTS FOR �,r�M°aro�°17h�+A 'sue: _,Na�1498-089,,�� 788452EFL HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 1157 5023 W Peoria Ave (Lot 1157), Glendale, AZ 85302 by PREFERRED APARTMENT BUILDERS exceeds the minimum requirements for the 2018 International Energy Conservation Code Ceiling Flat: NA Sealed Attic: NA Vaulted Ceiling: R-22.5 Above Grade Walls: R-13,0 Foundation Walls: NA Exposed Floor: NA Slab: R-0.0 Edge, R-0.0 Under Building Features Duct: R-4.2 Duct Leakage to Outside: 0.038 CFM25 / CFA Total Duct Leakage: 0.078 CFM25 / CFA Infiltration: Htg: 3.94 Clg: 3.94 ACH @ 50 Pascals Window: U-Value: 0.350, SHGC: 0.230 Air -Source HP: Electric, Htg: 7.5 HSPF2. Clg: 14.5 SEER2 Water Heating: Conventional , Electric, 0.92 EF, 40.0 Gal The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in compliance with Chapter 4 based on Climate Zone 2B and with all mandatory requirements. „ Digitally synod 6y James Srytes Date: 2g2 .10.18 12:3g:15 EDT Reason: „1. CN=James Styles, O=TOPBUILD HOME SERVICES, INC.. OU, Name James Styles Signature EMAILADDRESS=james.styles@topbuild.c , r c=us Organization TOPBUILD HOME SERVICES, INC. Date 10/1812024 The 2018 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. { "ICC"). No version of this software has been reviewed or approved by ICC or its affiliates. Ekotrope HERS Rating Tool - Version 4.2.2 A� ' " • ,, s Ho. r4saoe�; ENVIRONMENTS FOR a VDITATI � - Est Build �. Home Services 78M53EFL Tru, Branch Name: Branch Address: City/State/Zip: Mesa Branch 394- Emc Insulation 7107 E Southern Ave Suite 107 Mesa, Az 85209 Installed Insulation Certificate We certify that the insulation material listed here was installed at the address listed below: Aluminum Foam Loose Fill Kraft Unfaced Foil Open/Closed BIBS® R-Value Attic � ❑ R-22 Ceilings ❑ ❑ ❑ ❑ D ❑ Floors 0 El ❑ ❑ ❑ Walls El El 0 ❑ ❑ ❑ R-13 Basement ❑ El ❑ ❑ ❑ ❑ Crawlspace ❑ El El ❑ ❑ ❑ Other ❑ El 0 ❑ ❑ El R-19 Contractor (Signature) Title Sales/Estimation Other than loose fill 8 loose fill only aluminum foil only aluminum foil Initial Installed & No.of Coverage Minimum Settled Air Spaces Direction of Thickness Pkgs Area (SF) Thickness No Thickness Heat Flaw 6 Address or Lot Number: 5023 W Peoria City, STZip: Glendale, AZ, Unit 1156/1157 Date Installed: TT.OPS.FRM.010