Loading...
HomeMy WebLinkAbout162933 7715 N Cotton Ln Unit 164 Litchfield Park,AZ 85340 Builder:Lifestyle Homes AZ Model:Plan 1 Studio Community:Tavalo Cotton Lane THIS HOME IS CERTIFIED TO MEET THE INTERNATIONAL2018 • s Or Building Features Ceiling Vaulted Roof,R-22 Duct Supply R-6.0,Return R-6.0 Above Grade Walls R-17 Duct Leakage to Outside 23 CFM @ 25Pa(4/100 ft2) Foundation Walls N/A Total Duct Leakage 23 CFM @ 25Pa(Rough-In,with Air Handler) Framed Floor N/A Heating Air Source Heat Pump•Electric•8.2 HSPF Slab R-0.0 Perimeter,R-0.0 Under Cooling Air Source Heat Pump•Electric•14 SEER Infiltration 5 ACH50 Water Heating Residential Water Heater-Electric•0.92 Energy Window U-Value:0.3,SHGC:0.25 Factor As a 3rd party extension of the code jurisdiction utilizing these reports,I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on MARICOPA County.If rating is Projected,I certify that the building design described herein is consistent with the building plans, specifications,and other calculations submitted with the permit application.if rating is Confirmed,I certify that the address referenced above has bloc tested an at the mandatory provisions ofthe IECC have been installed to meet or exceed the intent ofthe IECC or will be verified as such by another party. Lam' Name: Derek Flick Signature: Organization: JKP Energy Inspections,LLC Digitally signed: 10/24/24 at 12:37 PM Ekotrope RATER-Version 4.2.1.3507 2018IECC compliance results calculated using Ekotrope RATERS energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool.All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Home Energy Rating Certificate Rating Date: 10/24/2024 Final Report Registry ID: 900838367 Ekotrope ID: 2Joz9m5L ■ D Index Score: Home: Your home's HERS score is a relative 7715 N Cotton $880 ■ ' + : + the • • home. • 52 leaFn more, ■- • to HERS Reference • Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtul Annual Cost criteria of the following: Heating 1.9 $65 ENERGY STAR V3.1 Cooling 14.7 $514 ENERGY STAR v3 Hot Water 5.8 $197 2018 International Energy Conservation Code Lights/Appliances 13.0 $444 Service Charges $149 Generation (e.g.Solar) 0.0 $0 Total: 35.5 $1,368 HERSIndex Home Feature Summary: Rating Completed by: .4glb., WMEMM Home Type: Duplex,single unit ISO Model: Plan 3 Energy Rater: Derek Flick Existlng l+o Community: Tavaio Cotton Lane RESNET ID: 4514441 Homes 130 Conditioned Floor Area: 1,276fe Rating Company: JKP Energy Inspections,LLC 120 Number of Bedrooms: 3 1410 W.Guadalupe Rd.Ste 124 Gilbert,AZ 85233 Reference . : I Primary Heating System: Air Source Heat Pump•Electric•8.2 HSPF 480-350-9274 HOnx 100 Primary Cooling System: Air Source Heat Pump.Electric.14 SEER •9° Rating Provider: JKP Energy Inspections,LLC .m Primary Water Heating: Residential Water Heater•Electric•0.42 Energy Factor .70 House Tightness: 5 ACH50(Adjusted Infiltration:5.00 ACH50) 1410 W.Guadalupe Rd.Ste 124 Gilbert,AZ 85233 •ao 480-350-9274� Ventilation: 42.8 CFM•14.98 Watts(Default).Supply Only . sow Duct Leakage to Outside: 51.04 CFM @ 25Pa(4/100 ft :3 A '10 Wsaimne Above Grade Walls: R-17 's,;:. ,;,,;+:,.,� •� Ceiling: Vaulted Roof,R-22-20 Window Type: U Value:0.3,SHGC:0.25 Zero me Ener 0 Foundation Walls: N/A mw, Framed Floor. N/A Derek Flick,Certified Energy Rater Digitally signed:10/24/24 at 12:35 PM Ekolrope MrEft-Version-4.2.13507 RatingThe Energy Disdowre for this homp ■ ■ Miting Provider. reportThis • ot constitute any warranty or quarants.-e. 7 715 N Cotton L n Unit 163 Litchfield Park, AZ 85340 Builder:Lifestyle Homes AZ Model:Plan 1 Studio Community:Tavalo Cotton Lane THIS HOME IS CERTIFIED TO MEET THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE Building Features Ceiling Vaulted Roof,R-22 Duct Supply R-6.0,Return R-6.0 Above Grade Walls R-17 Duct Leakage to Outside 23 CFM @ 25Pa(4/100 ft2) Foundation Walls N/A Total Duct Leakage 23 CFM @ 25Pa(Rough-In,with Air Handler) Framed Floor N/A Heating Air Source Heat Pump•Electric•8.2 HSPF Slab R-0.0 Perimeter,R-0.0 Under Cooling Air Source Heat Pump•Electric•14 SEER Infiltration 5 ACH50 Water Heating Residential Water Heater•Electric•0.92 Energy Window U-Value:0.3,SHGC:0.25 Factor Asa 3rd party extension of the code jurisdiction utilizing these reports,I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on MARICOPA County.if rating is Projected,I certify that the building design described herein is consistent with the building plans, specifications,and other calculations submitted with the permit application.if rating is Confirmed.I certify that the address referenced above has /tested an at the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will beverified as such by another parry. Name: Derek Flick Signature: Organization: JKP Energy Inspections,LLC Digitally signed: 10/24/24 at 12:37 PM Ekotrope RATER-Version 4.2.1.3507 20181ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS RatingTool.All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 0 LOD rA to CIJ CN CL Au P-4 06 rA 4 Cz] ¢�-O � � •w r'a t7 � � � ,� as .� ,� �. •ry � �, � ps•. �. s�-� i�i o*" 'dry. [� �*.�+ �` •;y'� W �"o 4- O N a p a W 4-0 co �, c� �, v K O Cd P. K a U U cn O U W ° Z O c a M Z o P4 gt V. Q cd z vi cd � O O M n cc a1 5 a� U Lon o Ln 88 ct x ° r � CIA Q d 0� y M >' ° o on Gn Cd . . •sue `*"O U Ov i cn x o c N v 0 O Q UD co to ,w N +' td N O •�+ � � J Q Q � 0f) cd 4-4 `` r O W ++ co a N W 4-1 a W a . s an $ Z � O a � o •� � W LnCD U ¢ o o M a d a N O cz 03 ■ • • 4- U y Ln U L� Ln C) N a Pam- PIT 1;31 rig px