Loading...
HomeMy WebLinkAbout162945 Home Energy Rating Certificate Rating Date: 2024-10-17 Final Report Registry ID: 507719835 Ekotrope ID: d 1 WRI31 a2 ■ v Index ScoYour home's HERS score is a relative 7715 N re: Cot-ton • Litchfieldperformance score.The lower the number, Park, AZ 85340 the more energy efficient the home.To $673 Builder: 54learn more, visit www.hersindex.com 'Relative to HERS Reference ■ Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu] Annual Cost criteria of the following: Heating 1.8 $60 ENERGY STAR v3.1 Cooling 12.3 $422 ENERGY STAR v3 Hot Water 4.8 $161 2018 International Energy Conservation Code Lights/Appliances 11.1 $375 Service Charges $149 Generation(e.g.Solar) 0.0 $0 Total: 30.0 $1,165 Home Feature Summary: Rating Completed by M�� M.'.r.■rpr Home Type: Duplex,single unit Model: Plan Energy Rater: Derek Flick EXIS u0 Community: Tavalo Cotton Lane RESNET ID:4514441 HOffm Conditioned Floor Area: 969 fe Rating Company:JKP Energy Inspections,LLC "D Number of Bedrooms: 2 1410 W.Guadalupe Rd.Ste 124 Gilbert,AZ 85233 t t 1 Primary Heating System: Air Source Heat Pump.Electric-8.2 HSPF 480-350-9274 MOON Primary Cooling System: Air Source Heat Pump-Electric•14 SEER to Primary Water Heating: Residential Water Neater-Electric-0.92 Energy Factor Rating Provider.JKP Energy Inspections,LLC m house Tightness 5 ACHSO(Adjusted Infiltration:4.86 ACH50) 1410 W.Guadalupe Rd,Ste 124 Gilbert,AZ 85233 48 w Ventilation: 32.2 CFM-11.27 Watts(Default)-Supply Only 0.350 9274 ;:-�•.,- Duct Leakage to Outside: 38.76 CFM @ 25Pa(4/100 ft� AO TI&N"�• Above Grade Walls: R-17 :l r. wr■ y0 Ceiling: Vaulted Roof,R-22ZErw ;'*m W Window Type: U-Value:0.3,5HGC:0.25 ° ►1 p Foundation Walls: N/A „ Framed Floor. N/A Derek Flick,Certified Energy Rater Digitally signed:10/29/24 at 10:32 AM ■ r Rating Disclosure for . ► Approved Rating Prrivider reportdoes not . or guarantee. 7715 N Cotton Lin Unit 167 Litchfield Park,AZ 85340 Builder:Lifestyle Homes AZ Model:Plan 2 Community:Tavalo Cotton Lane THIS HOME IS CERTIFIED TO MEET THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE Building Features Ceiling Vaulted Roof,R-22 Dud Supply R-6.0,Return R-6.0 Above Grade Walls R-17 Dud Leakage to Outside 38.76 CFM @ 25Pa(4/100 ft2) Foundation Walls N/A Total Dud Leakage 38.76 CFM @i 25Pa(Rough-In,with Air Handler) Framed Floor N/A Heating Air Source Heat Pump•Electric•8.2 HSPF Slab R-0.0 Perimeter,R-0.0 Under Cooling Air Source Heat Pump•Electric•14 SEER Infiltration 5 ACH50 Water Heating Residential Water Heater•Electric•0.92 Energy Window U-Value:03,SHGC:0.25 Factor Asa 3rd party extension of the code jurisdiction utiraJrvg these reports,I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on MARICOPA County.if rating is Projected,I certify that the building design described herein is consistent with the building plans, specifications,and other calculations submitted with the permit application.If rating is Confirmed,I certify that the address referenced above hast /tested an at the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Derek Flick Signature: Organization: JKP Energy Inspections,LLC Digitally signed: 10/29/24 at 10:32 AM Ekotrope RATER-Version 4.2.1.3510 2019 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tod.All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.