Loading...
HomeMy WebLinkAbout164969 Home Energy Rating Certificate Rating Date: 9/16/2024 Final Report Registry ID: 852927043 Ekotrope ID: 25YmrPp2 Index ■ - Annual Savings Your home's HERS score isa relative 7715 N Cotton Ln Unit 226 Litchfieldperformance score.The lower the number, Park,AZ 85340 Homesthe more energy efficient the home,To $673 Builder: 541earn more, visit www.hersindex.corn 'Relative to HERS Reference Home Life-style + Your Home's Estimated Energy Use: This home meets or exceeds the Use IMBtu] Annual Cost criteria of the following: Heating 1.8 $60 ENERGY STAR v3.1 Cooling 12.3 $422 ENERGY STAR v3 Hot Water 4.8 $161 2018 International Energy Conservation Code Lights/Appliances 11.1 $375 Service Charges $149 Generation (e.g.Solar) 0.0 $0 'total: 30.0 $1,165 Home Feature Summary: Rating Completed by: ,e11hp, "a vewo Home Type: Duplex,single unit im Model: Plan 2 Energy Rater: Derek Flick 140 Community: 7avalo Cotton Lane RESNETID:4514441 I" Conditioned Floor Area: 969 fe Rating Company:JKP Energy Inspections,LLC ImI Number of Bedrooms: 2 1410 W.Guadalupe Rd.Ste 124 Gilbert,AZ 85233 Re{m e ;im Primary Heating System: Air Source Heat Pump•Electric•8.2 HSPF 480-350-9274 me Primary Cooling System: Air Source Heat Pump•Electric•14 SEER .90 Rating Provider:JKP Energy Inspections,LLC so Primary Water Heating: Residential Water Heater•Electric•0.92 Energy Factor 1410 House Tightness 5 ACH50(Adjusted Infiltration:4.86 ACH50) Guadalupe Rd.Ste 124 Gilbert,AZ 85233 ao Ventilation: 32.2 CFM•11.27 Watts(Default)•Supply Only 480-0-350-9274 ~ ; SO-6 Duct Leakage to Outside: 38.76 CFM @ 25Pa(4!100 i° Ms mkxv Above Grade Walls: R-1730 1 Ceiling: Vaulted Roof,R-22.20 w Window Type: U-Value:0.3,5HGC.0.25 Zero Er" ,0 Foundation Walls: N/A w.bww Framed Floor. N/A Derek Flick,Certified Energy Rater oWu" Digitally signed:9/16124 at 12A2 PM . . Ratingekotrope The Energy Disclosure for This refxmt does nctl constitute any warranty or guarantee. 7715 N Cotton Ln Unit 226 Litchfield Park,AZ 85340 Builder:Lifestyle Homes AZ Model:Plan 2 Communi :Tavalo Cotton Lane THIS HOME IS CERTIFIED TO MEET THE INTERNATIONAL2018 • CODE Building Features Ceiling Vaulted Roof,R-22 Dud Supply R-6.0,Return R-6.0 Above Grade Walls,R-17 Duct Leakage to Outside 38.76 CFM @ 25Pa(4/100 ft2) Foundation Walls N/A Total Duct Leakage 38.76 CFM @ 25Pa(Rough-In,with Air Handler) Framed Floor N/A Heating Air Source Heat Pump•Electric•8.2 HSPF Slab R-0.0 Perimeter,R-0.0 Under Cooling Air Source Heat Pump•Electric•14 SEER Infiltration 5 ACH50 Water Heating Residential Water Heater-Electric•0.92 Energy Window U-Value:0.3,SHGC:0.25 Factor Asa 3rd party extension of the code jurisdiction utilizing these reports,I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on MARICOPA County.If rating is Projected,I certify that the building design described herein is consistent with the building plans, specifications,and other calculations submitted with the permit application.If rating is Confirmed,I certify that the address referenced above has ba d/tested and at the mandatory provisions of the IECC have been installed to meet or exceed the intent ofthe IECC or will be verified assuch by another party. Name: Derek Flick Signature: Organization: JKP Energy Inspections,LLC Digitally signed: 9/16/24at 12.42 PM Ekotrope RATER-Version 4.2.1.3481 20181KC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNETAccredited HERS Rating Tool.All results are based on data entered by Ekotrope users. Ekotrope disclaims all liabirdyforthe information shown on this report. r 0 o ti V O ^ 04 CD �. a o NCN V] Q � r N O Sx+ V N m c *� O eq a.+ � a U c�3 W 2 !� o Cd ors U rfi a • O o Q, o 3 C7 a a Z > ° -a a o ' OW kn � 'o a rw as w w �t C c z bb Cl) r., a f." U y U N cJ d. ct o`r'o o ` ° °' b CA cal $D, a) •• U a o � E- oo �r vCL ' cn cri U SA ) C—q w w P-� 4 � : ' ;;L a