HomeMy WebLinkAbout143027 L( an Y1 , rds Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers 5224 South 39th Street, Phoenix, Arizona 85040 tel: (602)438-2500 fax: (602)438-2505 ROC#291316 www.smleng.com September 1,2021 Mr.Luis Saravia Strong Tower Construction 7015 N 27th Avenue Phoenix,Arizona 85051 Re: Fire Damage Inspection Ted Williams Residence 11249 North 49th Drive Glendale AZ 85304 . SML Job#904-21 Dear Mr. Saravia: As requested, we performed a fire damage investigation at the above referenced property in Phoenix, AZ on Monday, August 30, 2021. The purpose of the site visit was to examine a single-family home for structural damages related to a recent fire and provide a structural fire damage assessment report and appropriate structural repair recommendations. OBSERVATIONS: This is a single-family home consisting of approximately 3 bedrooms and 2 bathrooms in Phoenix, AZ. Based on public records the residence resides on a 1,700 SF footprint with an original construction date of 1974. The home is framed with 4x8x16 CMU slump block walls and pre- manufactured wood roof trusses spaced at 24-inch centers. We assumed the foundations are comprised of conventional concrete slab-on-grade and shallow spread foundations.Demolition and cleanup had occurred prior to our inspection. The damages we observed appeared to be consistent with fire related damages based on our experience. At the time of our inspection,the fire appeared to be Iocated in the attic space above the guest bedrooms on the north side of the home. We found damages to the bottom chord of one roof truss. Non-structural soot and smoke damages were noted to the two adjacent trusses. The fire damages appeared to be fairly limited in their nature in that they did not rapidly spread out of the insulated depth of the truss bottom chords. Fire damages were not observed in the truss top chords or webbing or roof sheathing. We noted loss of section to the truss bottom chord that will require structural repairs as indicated below and in the attached repair details. We did not observe any damages to the roof sheathing or top chord due to fire department access or vent holes. Also, damages related to Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers Fire Damage Inspection Ted Williams Residence 11249 North 49th Drive Glendale AZ 85304 SML Job#904-21 exterior finishes, trim, eave and fascia boards and interior trim were relatively limited in nature other than the expected smoke and soot damages. We found extensive amounts of charred and missing attic insulation near the origin of the fire. We also found char damages to interior,non-bearing 2x framed walls around the guest bedroom door openings that will need to be removed and replaced with new 2x4 at 16-inch center stud framing. STRUCTURAL FIRE DAMAGE ASSESSMENT: 1. The No. 6 truss from the north gabled end was found to be structurally damaged by the fire with a missing and charred bottom chord that was removed for approximately (3) FT. The contractor should refer to SK-1 for this truss repair. The bottom chord should be structurally repaired by installing new 2x filler block material in the missing length and sistering new 2x4 materials to each side as shown in SK-4 and SK-5. 2. The interior wall directly below the No. 6 truss was damaged with char. This wall is an interior, demising, non-loading bearing, non-structural wall. It should be re-framed by conventional means as shown in SK-2 as a corner framing assembly. The contactor should account for approximately (4) 2x4 wall studs and single 2x4 top plate with Simpson DTC roof truss clips that allows the repaired truss above to deflect above the new wall top plate; reference repair detail SK-3.Any 2x flat ladder bracing that is found to be charred should be removed and reinstalled between truss bottom chords at 24-inches on center to brace the top of the interior 2x stud non-structural demising walls. 3. The exterior walls,the remaining roof trusses, the roof sheathing and the remaining interior walls, the concrete slab on grade floor, and the foundations were not structurally damaged by the fire and are structurally acceptable for use in the rebuild. Any remaining wood framing members with smoke / soot staining need to be cleaned and sealed per industry standards as required to prevent odor. Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers -2- Fire Damage Inspection Ted Williams.Residence 11249 North 49th Drive Glendale AZ 85304 SML Job#904-21 See the enclosed repair sketches,plans, details and general structural notes for the required structural repairs to the fire damaged elements. If additional structural damage is noted once the demolition and cleanup have been completed or during the rebuild, please contact our office to perform a follow up investigation.If you have any questions regarding our investigation or this report,please do not hesitate to call. Sincerely, STARLING MADISON LOFQUIST, INC. { r 6 tf1 ATE . D,® ms. �o a .Y P a 48716 S of i :p' d ANDREW J. I ;' o HUSEMAN AP c 9/01/2021 Sj n a d 1' EXPIRES 12/31/2023 Andrew J.Huseman,PE Principal Attachments: Photos, Repair Sketches&GSN Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers -3- , Fire Damage Inspection Ted Williams Residence 11249 North 49th Drive Glendale AZ 85304 SML Job#904-21 GENERAL STRUCTURAL NOTES FOR THE STRUCTURAL REPAIRS AT 11249 NORTH 49TH DRIVE GLENDALE AZ 85304 CODE: COMPLY WITH THE 2018 EDITION OF THE INTERNATIONAL / BUILDING CODE/INTERNATIONAL EXISTING BUILDING f 4%4 CODE/INTERNATIONAL RESIDENTIAL CODE ? �tiFscar£�.,. AND ALL AMENDENTS AS PART OF THE CITY OFm 40 'a y GLENDALE BUILDING CODE. ! .� I 48716 i ` 1 i 9 ANDREW J. < � o HUSEMAN rt ' Pn 9/01/2021 s, nad 4�/ZONA, 05. P SAFETY: EXPIRES 12/31/2023 PROJECT SAFETY IS THE RESPONSIBILITY OF THE CONTRACTOR OR PERSONS IN CHARGE OF THE DAY-TO-DAY CONSTRUCTION.UNSECURED ROOF JOISTS ARE SUBJECT TO ROLL OVER AND THEREFORE SHOULD NOT BE USED AS A WALKING SURFACE UNTIL THEY ARE SECURED AT BOTH SUPPORTS AND LATERALLY BRACED. NOTE TO CONTRACTOR: IF FOR ANY REASON THE DETAILS AND,INFORMATION CONTAINED ON THESE PLANS DO NOT CONFORM TO THE CONSTRUCTION SITE CONDITIONS, IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO PROMPTLY NOTIFY THE ENGINEER.THERE IS NO ACCEPTABLE EXCUSE FOR UNAUTHORIZED FIELD MODIFICATIONS. ' THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING, SHORING, GUYING OR OTHER MEANS TO AVOID EXCESSIVE STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING ERECTION.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR MECHANICAL, ELECTRICAL AND PLUMBING WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL VERIFY IN FIELD ALL EXISTING CONDITIONS SHOWN IN DRAWINGS. WOOD: SEE TABLE 2304.9.1 OF THE INTERNATIONAL BUILDING CODE (TABLE 602.3(1) FOR IRC) FOR TYPICAL NAILING SCHEDULE. CONNECTIONS: ALL NAILS REFERRED TO SHALL BE COMMON NAILS. ALL FRAMING CONNECTIONS SHALL BE MADE WITH METAL FRAMING ANCHORS. ALL LUMBER SHALL BE AS FOLLOWS:GRADED IN ACCORDANCE WITH WESTERN WOOD PRODUCTS ASSOCIATION OR WEST COAST LUMBER BOARD GRADING RULES. EACH PIECE SHALL BEAR THE STAMP OF AN APPROVED GRADING AGENCY. Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers -5- Fire Damage Inspection Ted Williams Residence 11249 North 49th Drive Glendale AZ 85304 SML Job#904-21 NAILING SCHEDULE: IBC TABLE 2304.9.1,USE COMMON NAILS. CONNECTORS: SIMPSON/STRONG-TIE OR APPROVED EQUAL. AT INTERIOR NON-BEARING STUD WALLS PROVIDE SINGLE TOP AND BOTTOM PLATES WITH BETWEEN 1/4"AND 1/2"GAP TO TRUSSES. ATTACH TOP PLATE TO TRUSS WITH SIMPSON DTC CLIP. FRAMING LUMBER:DOUGLAS FIR-LARCH,NO.2 OR BETTER PLYWOOD: REPAIR PLYWOOD SHALL BE 1/2"(15/32")APA RATED INDEX 32/16 C-D WITH EXTERIOR GRADE GLUE AND WITH ONE PLY CLIP AT UNBLOCKED EDGE. OSB APA RATED 2MW.NAIL WITH 8d NAILS AT 6"O.C.AT EXTERIOR EDGES AND 12"O.C.INTERIOR. LAY UP WITH FACE GRAIN PERPENDICULAR TO SUPPORTS MINIMUM 2 SPAN CONTINUOUS. CONSTRUCTION ADHESIVE: LOCTITE PL PREMIUM POLYURETHANE ADHESIVE OR APPROVED EQUAL. SURFACES TO BE GLUED MUST BE WIPED CLEAN.APPLY ADHESIVE IN 3/8" DIAMETER BEAD. APPLY SUFFICIENT ADHESIVE TO PROVIDE COMPLETE SURFACE COVERAGE AND CREATE MINOR VISIBLE SQUEEZEOUT. NAILS OR SCREWS MUST BE INSTALLED AND DRIVEN TIGHT WITHIN 10 MINUTES OF ASSEMBLY. TEMPORARY CLAMPS MUST BE INSTALLED IF NAILS OR SCREWS CANNOT BE INSTALLED WITHIN 10 MINUTES. TIGHT GLUE JOINTS ARE REQUIRED IN ALL LOCATIONS. Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers -6- . 0 NEW 2x4x8'-O" LONG EACH SIDE - v ATTACH W/ IOd NAILS OR NO. 8 WOOD SCREWS AT 6" O.G. STAGGERED TOP ✓!: BOTTOM REMOVE FIRE DAMAGED SECTION - OF BOTTOM CHORD (a 56") - SQUARE END it ADD 2x FILLER BLOCK 8 SHIM FOR SNUG FIT 0 TRUSS ELEVATION bth ROOF TRUSS SOUTH OF NORTH GABLE END SCALE: I/4"=I'-O" PRELIMfNA;Y •SIGNED AND SEALED DRAWN BY: T.M. DATE: 8-31-2021 fsetona/ DESIGNED BY: A.H. JOB NO: 904-21 y ,� Ar �v� 5 Starling Madison Lofquist, Inc. Q, ` etio 'mm,, 5224 S. 39th Street 4871 s STRONG TOWER ' ANDREW J. Phoenix, Arizona 85040 FIRE DAMAGE REPAIR CONSTRUCTION ':' ,0 HUSEMA'N� 1 (602) 438-2500 11249 N. 49th DRIVE 7015 N. 27th AVENUE X® eV'� fax. (602) 438-2505 GLENDALE,AZ 85304 RIZONA 8 1 s,PHOENIX,A 505 ned Consulting Structural and 4R/20N U.`''P� Forensic Engineers _ A. EXPIRES 12/31/2023 . 5 FIRE DAMAGE REPAIR x q ` E E'a4' �' Starling Madison Lofquist, Inc: 11249 N. 49th DRIVE 4. est 6616e1 h do e® 5224 S. 39th Street GLENDALE,AZ 85304 ply 48716 -- . - Phoenix, Arizona 85040 1} 0 ANDREW J. (602) 438-2500 , HUSEN i Consulting Structural and fax. (602) 438-2505 t STRONG TOWER ( S� ned o Forensic Engineers CONSTRUCTION ' .4VoNA 0-$P. ! 7015 N. 27th AVENUE DRAWN BY: T.M. DATE: 8-31-2021 f PHOENIX,ARIZONA 85051 1 EXPIRES 12/31/2023 DESIGNED BY: � A.H. JOB NO:____ 904-21 j�� - ___-._ �.PREIJMINARYIFNOTSIGNEDANDSEALED EDGE NAILING I6d AT12" O.G. STAGGERED PLYWOOD SHEATHING ihrimair•A 1 LAME- mi ..-.-Al I STUD WALLS, TYP. I6d AT 12" O.G. I6d AT STAGGERED 12" O.G. I6d AT 12" O.G. AT INTERSECTIONS EDGE NAILING I6d AT 12" O.G. AT EA. MEMBER PLYWOOD 51 IEATH ING I Kw, PE M1;-- P.IIITAMITs_ "Ming 2x MIN. BLOCKING AT CORNERS • TYR. STUD !'1ALL CONNECTION SCALE: 3/4"=I'-O" ` s rs`Af6na, FIRE DAMAGE REPAIR f ��Flcnr o, 5Starling Madison Lofquist, Inc.{ 11249 N.49th DRIVE l e 4i� f'yo 5224 S. 39th Street }� GLENDALE,AZ 85304 ry 4g715 ------ , . ---.--- Phoenix, Arizona 85040 I ANDREW J (602) 438-2500 1 HUSEM�N ` ConsultingStructural and fax. (602) 438-2505 f STRONG TOWER sine � j Forensic Engineers CONSTRUCTION i q 41/20NA. U. ---��A �- 7015 N. 27th AVENUE DRAWN BY: T.M.T.M. ' •DATE 8-31-2021- PHOENIX,ARIZONA 85051 I EXPIRES 12/31/2Q23 _ DESIGNED BY: A.H. ill JOB NO: ^� 904-21 ^-��- IIPRELIMINARYIF NOT SIGNEDAND SEALED a� �� � 51I iPSON DTG SLOTTED --- TRUSS CLIP AT 24" O.G. • IIIIMIIIIIIIIrIMIIIIIM I/4" GAP AFTER ROOF DEAD LOAD HA5 BEEN APPLIED • NON-SEARING WALL AT TOP SGALE: 3/4"=I'—O" • 5 Starling Madison Lofquist, Inc. FIRE DAMAGE REPAIR cat �'D 11249 N.49th DRIVE c�1` Fyo 'mm^ 5224 S. 39th Street ij GLENDALE,AZ 85304 48716 - Phoenix, Arizona 85040 ►� M I '1 • ' ANDREW a -s (602) 438-2500 f X HUSEM i ` Consulting Structural and fax. (602) 438-2505 STRONG TOWER J o sA �� e Forensic Engineers CONSTRUCTION 4R�I0NA. V.S N 7015 N. 27th AVENUE DRAWN BY: r T.M. DATE: a 8-31-2021 PHOENIX,ARIZONA 85051 _ EXPIRES 12/31/2023 DESIGNED BY: A.H. j JOB NO:- 904-21 ��_� PREUMINARYIF NOT SIGNED AND SF.ALED IOd NAILS OR NO. 8 EXISTING 2x WOOD SCREWS AT TRUSS MEMBER 6" O.G. STAGGERED WWI \EE1kI { Arai ,1 " -1.1 ADD 2x D.F. #2 HEIGHT TO MATCH EXISTING NOTE: SEE DETAIL 5 FOR SECTION NAILING/ SGREW PATTERN. SCALE: 11/2"=I'-O" 6" 6" 6" 6" 11/2" 1 I I I 1 I _ t t O O - • - IOd NAILS OR NO. & WOOD SCREWS AT . 6" O.G. STAGGERED Cl TYP I GAL FASTENER DETAIL SCALE: I I/2"=ILO"