Loading...
HomeMy WebLinkAbout1027754 H FROM : ENO PARTNERSHIP PHONE NO. : 6222743543 Oct. 17 2000 04:34PM P1 _ THE • ENG PARTNERSHIP • STRUCTURAL ENGINEERS 5045 N. 12th Street,Suite 136•Phoenix,Arizona 55014-3375•1602)274-7243•F2x MS02)274.3543 October 17;2000 Bade Commercial Services, Inc. • • 8251 West Thunderbird Road . . . Peoria;,Arizona=85381 Attn: Roy Bade • • • . RE: THUNDERBIRD PALMS -PHASE I 5750 WEST THUNDERBIRD ROAD • • • GLENDALE,ARIZONA Dear Roy: • - -- ,--• • • .: This is to clarify your recent questions on structural masonry requirements for this project. Hopefully .. -•• •..the following will.address your concerns: .• AY. .. Structural Masonry Reinforcing 1, • Disregard masonry reinforcing notes 2,3&4 noted on general note sheet S I l under , -the"Masonry„heading. . 2, ;Standard wall reinforcing should be#5 @ 43"o.c.. • 3. Special wall pier reinforcing should be as noted on Detail 16 of S4.1. 16 and 32.inch - . wide'wall piers may have 1-#5 vertical each end. Allwall piers 48 inches aide and . . less should be grouted solid. • . . 4. Special pilaster reinforcing required at roof beam bearing points should be as noted. • • . •• on the foundation•plans and details and applicable beam to wall details. Ref 17 of• S4.1, . 20 of S4.2 and Details 3 and 5 of S4.3. • • . . . . FR M : ENG PARTNERSHIP PHONE NO. : 6022743543 Oct. 17 2O O D4:35PM P2 ' n THUNDERBIRD PALMS-PHASE 1 10/17/00 PAGE 2 B) Structural Masonry Special Inspection All of the structural masonry on this project,including wall piers and pilasters,was designed for one-half of the allowable stresses as per 1997 U.B.C. Section 2107.1.2. Based on this half stress design, special inspection per U.B.C. Section 1701 is not required. It was our understanding that the City of Glendale plan reviewer asked for special inspection of the pilasters only and not for the balance of the walls. We questioned this requirement since the . one-half stress design was clearly shown in our calculations. It was decided at the time to concede to inspection of the pilasters only in order to expedite approval of the building permit. Again,special inspection of the structural masonry is not required by this office based • • • on our design. This unnecessary requirement will create undue costs for your firm. It may be worth an attempt to have the building department waive this requirement, Please contact us if there are any additional questions on these issues. ` —_.: Reviewed: Sincerely, -_- - - • Gilbert R. Angulo Principal • quo"° � „e, _ • A. . . 12526 . �b_ '•'EDWARD M. SOTO . e • J• \ e E. .•.• •.E. . SemoF Pnnctpal � - - ---- - - --- -- ---- -----= —- c.c. Dustin Curtis, A.I.A. Wkdwink-edeninMtic-c izAWYWtN\aN.:-1i 11•11-nt biedninflTO-pd • • • • .�