Loading...
HomeMy WebLinkAbout42472 G •4, ', s OSA & DUCT DETECTOR REPORT t. .........._.. z Project: Corning Gilbert 5310 West Camelback Glendale, Arizona �N MAP Job # 08-1089 MAP TEST.AND BALANCE i Architect: T2 Architecture Group, LLC ri� ,' 7227 North 16th Street, Suite 125 Phoenix Arizona As F 4 £} ( g3yg ' f 4'I ?� x `" Y ;f 641 N. Hall f ""k Engineer: Air-Zona Systems Engineering, Inc. Mesa, AZ 85203 4531 N. 16th St., Suite 114 Phoenix, Arizona k 1 � 4 #zQ eS v r z 9 "i g�' General Contractor: John Bond Contracting Phone (4$0) 275 6970Y 1 5201 E. Charter Oak Road `Fax (480) 287 9673 Email mapta cox net = , , Scottsdale, Arizona 4 1 1 1 I .... , x -,:&-ts-voilAN a " .. OSA TEST REPORT P PROJECT: Corning Gilbert LOCATION: 5310 West Camelback Glendale, Arizona UNIT SERVED LOCATION DESIGN PREM. FINAL PERCENT NOTES OSA OSA OSA OF DESIGN EAC-1 1 Roof 360 371 371 103% EAC-2 2 Roof 360 380 380 106%. EAC-3 3 Roof 360 364 364 101% EAC-4 4 Roof 200 211 211 106% EAC-5 5 Roof 720 723 723 100% EAC-6 6 Roof 720 728 • 728 101% HP-1 7 Roof 200 210 210 105% HP-2 8 Roof 200 213 213 107% HP-3 9 Roof 200 215 215 108% HP-4 10 Roof 600 631 631 105% 11 12 13 14 15 NOTES: Technician: M.R. Gifford Test Date: April 04, 2008 Page 2 081089-Corning Gilbert sr T 3t1. ' " ' ,,,' 1.1 ash st �. . m F 8¢ '� CERTIFICATION PROJECT: Corning Gilbert ADDRESS: 5310 West Camelback Glendale, Arizona This report consists of two (2) pages. The cover sheet and this certification are included with this seal. The data presented in this report is a record of system performance and was obtained in accordance with SMACA and/or ASHRAE standards. Any variances from design quantities which exceed tolerances are noted throughout this report. * All duct smoke detectors were tested with aerosol smoke, which met the manufacturer's requirements. The design data was acquired from the information listed in the manufactures "submittal" which was on site at the time the tests were performed. Installation of the duct detectors, wiring to fire panel ( if applicable), and all other manufactures installation requirements have been met. Each duct detector has an audio/visual remote device which signals when the individual duct detector goes into alarm. All duct detectors are interlocked and when any individual duct detector detects smoke all units within the space shut down. SUBMITTED BY: Michael R. Gifford CERTIFIED BY: Medhat S. Nakhla Ve$NonaI En 4,� . a ,A\FICArey 61 Z.2). 30129 MEDHAT S. a o,e Sig ne,, F kk r _' € Duct Smoke Detector Test Report PROJECT: Corning Gilbert LOCATION: 5310 West Camelback Glendale, Arizona SMOKE DETECTOR VELOCITY FPM DIFFERENTIAL PRESSURE SAMPLE FIRE PANEL SMOKE FAN NO. INCHES W.C. TUBE ADDRESS/ TEST SHUT PASS FAIL NOTES LENGTH' ZONE OFF TIME MANUFACTURER MODEL NUMBER LISTED ACTUAL LISTED ACTUAL EAC-1 System Sensor DH100ACDCLP 100-4000 295 0.0015 to 1.2 0.33 PASS N/A 0 Seconds X EAC-2 System Sensor DH100ACDCLP 100-4000 318 0.0015 to 1.2 0.21 PASS N/A 0 Seconds X EAC-3 System Sensor DH100ACDCLP 100-4000 407 0.0015 to 1.2 0.25 PASS N/A 0 Seconds X EAC-4 System Sensor DH100ACDCLP 100-4000 241 0.0015 to 1.2 0.24 PASS N/A 0 Seconds X EAC-5 System Sensor DH100ACDCLP 100-4000 266 0.0015 to 1.2 0.37 PASS N/A 0 Seconds X EAC-6 System Sensor DH100ACDCLP 100-4000 342 0.0015 to 1.2 0.31 PASS N/A 0 Seconds X HP-1 System Sensor DH100ACDCLP 100-4000 371 0.0015 to 1.2 0.32 PASS N/A 0 Seconds X HP-2 System Sensor DH100ACDCLP 100-4000 411 0.0015 to 1.2 0.20 PASS N/A 0 Seconds X HP-3 System Sensor DH100ACDCLP 100-4000 284 0.0015 to 1.2 0.26 PASS N/A 0 Seconds X HP-4 System Sensor DH100ACDCLP 100-4000 290 0.0015 to 1.2 0.30 PASS N/A 0 Seconds X NOTES: Technician: M.R. Gifford Test Date: April 04, 2008 Page 1 081089-Corning Gilbert , - . �� i. � "<r e 1 awe v � " , *4•• • *.,,,:: :-5":'ef,,,c;.?. ' OSA TEST REPORT PROJECT: Corning Gilbert LOCATION: 5310 West Camelback Glendale, Arizona DESIGN PREM. FINAL PERCENT UNIT SERVED LOCATION NOTES OSA OSA OSA OF DESIGN EAC-1 1 Roof 360 371 371 103% EAC-2 2 Roof 360 380 380 106% EAC-3 3 Roof 360 364 364 101% EAC-4 4 Roof 200 211 211 106% EAC-5 5 Roof 720 723 723 100% EAC-6 6 Roof 720 728 728 101% HP-1 7 Roof 200 210 210 105% I HP-2 8 Roof 200 213 213 107% HP-3 9 Roof 200 215 215 108% HP-4 10 Roof 600 631 631 105% 11 12 13 i 14 1 15 1 NOTES: Technician: M.R. Gifford Test Date: April 04, 2008 Page 2 081089-Corning Gilbert