HomeMy WebLinkAbout00000 (8) SMOKE DETECTOR INSPECTION
ARIZONA AIR BALANCE COMPANY
624 S. PERRY LANE,SUITE 102 • TEMPE,ARIZONA • 480.966.2001
MEMBER OF ASSOCIATED AIR BALANCE COUNCIL AABC
PROJECT: Corning Gilbert PAGE: 1 OF 1
ADDRESS: 5310 W. Camelback Rd. DATE: 10/20/09
Phoenix, Arizona 85031-1130 BY: CG-JB
Smoke detectors have been inspected per the tasks listed. Variations or exceptions to a passing
condition are identified with a numbered note. Performance tests are for equipment function on
date tested. If the building owner or any representative of the building owner observes or believes
a deficiency is present, modifications have been made, or six months have passed since this
testing, the system must be reinspected and retested.
MANUFACTURER:System Sensor MODEL:D4120
UNIT DUCT SAMPLE RATED TEST FAN ALARM ALARM TEST
AND SIZE TUBE A P "WC A P SHUT VISUAL FIRE DATE
LOCATION W x H LENGTH MIN —> MAX "WC DOWN AUDIBLE PANEL
RA Duct Pass
32 x 35 36" 0.01 .—> 1.11 0.12 Pass Pass Not App. 10/20/09
AC-2 32 x 35 36" 0.01 —> 1.11 0.13 Pass Pass Not App. 10/20/09
RA Duct Pass
AC-3
RA Duct 32 x 35 36" 0.01 —> 1.11 0.09 Pass Pass
Pass Not App. 10/20/09
RA Duct Pass
35 x 32 30" 0.01 —> 1.11 0.13 Pass Pass Not App. 10/20/09
INSPECTION TASKS (AS APPLICABLE)
DELTA PRESSURE: As measured across the detector sampling tubes.
FAN SHUT DOWN: Tested for immediate shut down when detector is challenged with canned smoke.
Fan shut down is GLOBAL.
VISUAL ALARM: Lighting of remote test/indicator unit:Green pilot,amber trouble,red alarm.
(Remote test/indicator unit not required if detector is visible from floor.)
AUDIBLE ALARM: Sounding of remote test/indicator unit(not required in all municipalities).
FIRE PANEL ALARM: Alarm reports to central fire panel(remote test/indicator unit not then required).
NOTES
aalanc�;
(PI'�O OR Bq(4�0 d
gi
• • o •
re?O 87-o1'1
a
aerick A.See
CORNING GILBERT
PHOENIX, ARIZONA
• r.
TT...AN ..:: AN:::.`';:>:E`<` >..
PROVIDED BY
ARIZONA AIR BALANCE COMPANY
TEMPE, ARIZONA
•
MEMBER
ASSOCIATED AIR BALANCE COUNCIL
AABC
. MI
--11---iisaii ARIZONA AIR BALANCE COMPANY
HVAC TEST&BALANCE • PERFORMANCE SURVEY&MONITORING • CLEAN ROOM BALANCE
CORNING GILBERT
PHOENIX, ARIZONA
HVAC TEST, ADJUST, BALANCE REPORT
OCTOBER 20, 2009
ENGINEER
SEQUOIA TRAIL ENGINEERS
PHOENIX,ARIZONA
MECHANICAL CONTRACTOR
TOLIN MECHANICAL
PHOENIX,ARIZONA
PROVIDED BY
ARIZONA AIR BALANCE COMPANY
TEMPE,ARIZONA
_.‘t Balance e
,e
• p BAL4k •�,
!k3Lt'
...,.. „...,, _ „....:
e o . o
As,- e.87-0eea
`lerickA-5
Voice (480) 966-2001 • Fax (480) 966-2197 • info@arizonaairbalance.com
ROC Lic 082357 • AABC 87-01-26
624 South Perry Lane • Suite 102 • Tempe, Arizona 85281
-.: -r'r:z 7A- F7:•i^_ 'r.•.e— •s-Fi.::-sf�$.P7:::.� :n,:otisys'iap, .:r,:tiy. orr,1 _ S ;•.-r ��. / ?. 7.4e:;~'r.-o:.'='n
r''"x:��'e:,49'+°'':••J��+�<::?.e •:•oib .::l '1`ici�:� r^i :%��. .p�+�.1 I��,•�•,�/'3fi4 oZi�,.4•S.,..,.4ed.O'4,0: `;fi,V•:...�,,,0:�% .....o�.°�i• .Irl.; . ....''`. t'�p�'...„,,
E / + 4 In , 1/ 1,,h1// A.1 ,1 11
'tom�_'% "r ,�,, f ��+� .1h� s�tM1/14 4�'/9 �11,f IhF 1 ,I,/,I�y �o�',+1, R IP, I �1'1tl'tNi,1 'o�� 1le H' .n,�/ ,', e r t r�' �, � �'1 �� a
- i��:?liil f,/VP KA "I''Vi f t qg 4ftt t 'tV 4 f " t +141' 1:it a,, + g f +t t 11 f! g ' `44 st l 4 f t,+ i fy =. r>p
/ • ice,
�Hh'yO " J,1�
. MS< ...,--.Th AzzjiBc N to ,,,..„,▪IA,
li
11 National
el
,.`f i ; ( i NA
may o irP
r" Ml,
,
pitz:1,:--- Performance Guaranty —2---31'33 f
=ryy « Pursuant to the agreement between • *�
(«,L ti, Arizona Air Balance Company ` 110
(416 AABC Certified Testing& Balancing Agency 7Iit,
Tolin Mechanical =: ,�r
--- ;a:▪ : and = S
'�1::° " Client (` __�; ,,
01
(f(• "' •
All systems shall be tested and balanced in accordance with the project plans and specifications '�I
;.^4'=`= and to the optimumperformance capabilities of the equipment Testingand balancingshall be done .'.I
�IPt'�;✓�;,) p� p eq .p ,� .y.��
1•y.:
a� "' in accordance with the standards published by the Associated Air Balance Council. 4,.
`°" W`,., If the Agency listed above fails to comply with the specifications for any reason other than .1,1$1
u' =_- termination of business by the AABC agency or equipment malfunction or inadequacy which "�
r`=
0... , prevents proper balancing of the systems, AABC will investigate and, if warranted, will provide ;�_,
��'%.-�_
;;'� supervisory personnel to assist the member Agency to perform work in accordance with AABC - _.a�• '
;.:f, ,,. Standards.This supervision will be provided at no additional cost to the building owner. ,
At' �=�+ayrt
L a
,rt== This Guarantyis valid for one year from the date of submission of a test and balance report, 1—,
'E'�;.: provided the Agency is a current member of AABC,and may only be invoked in writing by the building _ �'
/I,+:: - .., owner, architect, or engineer of record. The Guaranty is limited to the terms and conditions as stated , Niilit
"-s.= herein. -
(ws_�'�=��- Project Name Corning Gilbert '== -
:- 5310 W. Camelback Rd. ` -:'S
'q i," Address _ :'
° ; - Phoenix, AZ 85031 (T ,i Ai'
Mr. Larry Evans, P.E. ,,0ti"�R„
{I�;r;,:4; Name of Engineer _ ‘ >I�I.
: - Sequoia Trail Engineers, LLC- ?'1
11: Engineering Firm q g a, syi}
ht T �
' Email Address tarry@steaz.net ',;w,�
o,'s t:: Address 7227 N. 16th St., Ste. 225 01
��' • — Phoenix AZ 85020 ! ' ♦.^,1
l/h- _� 10/20/2009yI;
,• t
". « date Associated Air
(1I,i Balance Council , . '
�==-= TBE#87-01-26 = :�
,ret----- 1518 K Street,N.W. ti- ll,
oxi: ; Washington,D.C.20005 . f
f4 gy Mr. Frederick A. Seed 202-737-0202•Fax 202-638-4833
-�;�'�I
"?,WS. AABC Certified TBE info@aabc.com•www.aabc.com e:�'�,,1
�4= 1�4U 4 1 ( +1fie 4.11l 4 ` + ' +j 1, f/1 4-:-.4l1ija"t ))f 051 t ,i' igi i�'i1 ft 16444 4144 lei tl 11 f1 114 4 a'ire; �
st.✓. ; 'A 44 o f11 :1 till i , 1 i 4 C /N.3 r1. i�' 4 'yl, .' a. 1'i "" �' �f''' iJi ! 1'�1 1 r ,,,.,p" 4 g °�` 1 N ", ,� •v >1{11, NN i 1 b 1 ��, +�, ��y y' a�lyy�,��•.: 1
h�V&V640 A. 1 ♦• ,k A.9*/$1 �.01111 9 W �14,11`A 41'4w�'I'T1// #.:: 1 1 '#f` 1N111 -11 11' 'I` A11` 111 1,� `II3 1 r/ /,f/4//1 1,t711,rop
414..,:::3 ISD..� 4413e♦;04:1.�:11��..1�141,4..Ir.04,1. 1;}♦.tat1�hr1S4t.i.1.4430�//4$:..{0-4:itt,It'.':OOie/{/j1���•i0!/sW. :34:-4:Agg�1.11}.A:VI1tsh::e;:;:.QIt�d V.i.4�ti.:::t4F•a•Sti.trio
.'74'7 -s::; ' 'v4-t-5f: �f swi:77-FA'.7-$;-r.'z v4.-A7 zs`r�z:.•✓ \'lit-_7\-?-:pr z f s _71r. •zz 7r ,:fir_•zv✓r__..�.�� _-.1rs 5.;.s=__r-;_e _>>;i=
A.
MIMI ARIZONA AIR BALANCE COMPANY ' AIR DISTRIBUTION
PAGE: 1 of 2
PROJECT: Corning Gilbert - Phoenix, Arizona DATE: 10/13/09
SYSTEM: AC-1, AC-2, AC-3 and AC-4 Outside Air BY: CG-JB
UNIT TERMINAL „K DESIGN PRELIMINARY FINAL NOTES
NO. NO. SIZE FPM CFM FPM CFM FPM CFM
AC-1 OSA 25x32 (x3) 16.66 96 1600 101 1680 101 1680 (1)
AC-2 OSA 25x32 (x3) 16.66 96 1600 563 9380 94 1565
AC-3 OSA 25x32 (x3) 16.66 96 1600 548 9130 98 1630
_ _ -AC-4 OSA 25x32(x3) 16.66- 96 1600 212 3530 103 1715 (1)
NOTES: (1) OSA damper does not respond to minimum position potentiometer. Linkage was adjusted to
obtain design CFM and the position marked on the shaft.
rARIZONA AIR BALANCE COMPANY Al R DISTRIBUTION
PAGE: 2 of 2
PROJECT: Corning Gilbert - Phoenix, Arizona DATE: 10/13/09
SYSTEM: AC-1, AC-2, AC-3 and AC-4 Traverse BY: CG-JB
ROOM TERMINAL ��K,� DESIGN PRELIMINARY FINAL NOTES
NO. NO. SIZE FPM CFM FPM CFM FPM CFM
AC-1 35x22 5.34 1872 10,000 1827 9755 1881 10,045 (1)
AC-2 35x22 5.34 1872 10,000 1873 10,005 1873 10,005 (1)
AC-3 35x22 5.34 1872 10,000 , 1876 10,020 1876 10,020 (1)
_ AC-4 35x22 5.34 1872 10,000 1882 10,055 1882 10,055 (1)
NOTES: (1) Set unit to nominal capacity of 10,000 CFM.