HomeMy WebLinkAbout1 ! �♦� Building Safety Department
artment
CiETID DAMAGED/DANGEROUS BUILDING
FIELD REPORT
Address: 6821 N. 45 Ave. Apt 19
Requested By: Will with Leos Construction
Phone Number • 623-386-3730 623-640-9288 cell
Council District:
Inspector: Mike Date: 10/29/04
Secured Y/N Method Utility Disconnected Elec. Y/N Gas Y/N
Permits Req'd: Bldg. ❑ Elec. ❑ Mech. ❑ Plumb. ❑ Combo ❑
DSC # Demo Permit # Date Issued
o Engineer to provide for Fix of cut trusses. Also, need report for lintel condition.
o Rewire electrical per code.
o Required 5/8" drywall for ceiling and party wall.
❑ Firestop party wall 10' on center.
❑ Replace all ducts and A/C unit.
o All new plbg. Fixtures required.
o New exhaust fans required.
o Bedroom egress height and size to meet 2003 IRC requirements.
o Smoke detectors to be installed per code requirements.
❑ Replace north fascia as needed.
o Replace roof sheathing and shingles as needed.
o Strongly recommend that the electrical service panel be changed out since Arc
Fault circuit breakers are probably unavailable for the panel boxes there and it is
almost impossible to gain access to the existing panel.
❑ Items not specifically addressed on this report shall meet the following codes.
o Note: The following Codes are in effect for this rebuild: 2003 IRC; 2003 IMC;
2002 NEC; 1994 UPC; All with City and State Amendments as Adopted by the
City of Glendale.
Permit Fee: Investigation Fee: Plan Review Fee:
N:COMMDEV\BLDGSAFETY\ABATEMENTS\FIELD REPORT.DOC,
REV:6/02
r
JF r J sequoia Wan Engineering LLC
July 17, 2009
Dietz Design, LLC
6650 N.47m Avenue, Suite 1
Glendale, Arizona 85301
Attn: Jeff Dietz, AIA
Re: Autumn Leaves Apartments—Electrical Grounding issues
STE Project#09016
Jeff
This letter is in response to the Correction notice receive from the City of Glendale on 7/15/2009.
If the ground system is no longer available we will need to provide a new Grounding Electrode
Conductor and per NEC Table 250.66 shall be min of 1/Ocu.
Per NEC 250.52 the Grounding electrode system needs to connect the water piping system, metal
building steel and ufer. Since the only one that exists for our project is the water piping we will need to
a supplemental grounding means as per NEC 250.52(A)(4)thru (7)which is a ground ring, ground rods,
or plate electrodes. The only viable option for an existing structure is the ground rods.
Per NEC 250.52(A)(5) have the contractor install 3 new 3/4th in diameter by 10 foot long. Per NEC
250.56 the ground rods shall be installed not less than 6' apart. If the space is available a triangular
layout would be desired.
If you should have any questions or need additional information please contact me at your earliest
convenience.
r3S921Greg .Larson,P.E.Sequoia Trail Engineers, LLC
1 E S t2 J'-
7227 North 16th Street, #225 • Phoenix, Arizona 85020 • 602-997-2999 • Fax 602-997-2957 • info@steaz.net