Loading...
HomeMy WebLinkAbout28519 O S S EMSRCIAL ANALYSIS R.O.C.#099027 H.V.A.C. Independent Testing & Balancing Air • Water • Sound • Vibration Active member of the National Environmental Balancing Bureau (NEBB) Certification No. NF-3129-09 Job: The Orthopedic Clinic Associates P.C. — Suite 185 6320 W. Union Hills Drive - Bldg. B Date: 7-06-06 Glendale, Arizona Page: 1 of 2 TEST CERTIFICATION FOR: SMOKE DETECTOR AIR PRESSURE DIFFERENTIAL INCLUDING SMOKE TEST AND EQUIPMENT SHUT DOWN VERIFICATION Permit#: 28519 Permit Date: May 9, 2006 Sensor Type: Photoelectric Head Visual Inspection: Commercial Systems Analysis (CSA) certifies to the best of our knowledge that the following smoke detectors are installed as close to what is physically possible (due to structural limitations and/or duct configuration) in accordance to the manufacturer's recommendation. Because of turbulence, there are slight fluctuations in the air pressure readings, therefore the following data are the lowest readings measured to assure compliance. These smoke detectors are secured to the duct with the correct length sampling tube properly inserted into the air stream with a factory red cap in the end. Electrical Inspection: The following split system Heat Pump units have one smoke detector installed in the return duct and are "powered up"with 120 volts supplied through a dedicated circuit from the electrical panel. These smoke detectors are not being monitored through any fire control panel. A functional remote LED indicator with audible alarm is installed in the ceiling tile below the respective smoke detector. Functional Test: *Airflow verification completed. The following test results(including operating temperature & humidity range and duct air velocities) are within the manufacturer's specifications. Measurements were taken with an Airdata Multimeter Model#ADM-870 electronic Micromanometer manufactured by Shortridge Instruments, Inc. Instrument certification of calibration date is 7-13-05. **Automatic shutoff verification completed. The following split system Heat Pump units de-energize immediately through the respective smoke detector when activated using canned smoke. Special Inspector: Joe Wahl Kurt M. Wahl NEBB Qualified S stemss qs o\? di &'( o L 0i�4 WAH U AT 3129 Exp.12/31/05 -9� G � d dron•lc S� d 5� ' 10443 N. Cave Creek Road • Ste.207 • Phoenix, Arizona 85020 • (602) 997-8938 • Fax (602) 997- 0 SYYS EMSRCIAL ANALYSIS R.O.C.#099027 H.V.A.C. Independent Testing & Balancing Air • Water • Sound • Vibration Active member of the National Environmental Balancing Bureau (NEBB) Certification No. NF-3129-09 Job: The Orthopedic Clinic Associates P.C. - Suite 185 6320 W. Union Hills Drive - Bldg. B Date: 7-06-06 Glendale, Arizona Page: 2 of 2 TEST CERTIFICATION FOR: SMOKE DETECTOR AIR PRESSURE DIFFERENTIAL INCLUDING SMOKE TEST AND EQUIPMENT SHUT DOWN VERIFICATION Required * Actual **Smoke Unit Make Model Duct Duct Probe Delta Delta Test Location Width Length Pressure Pressure Results (Inches w.c.) (Inches w.c.) AH-1 Air Products SL-2000-P Return 36" 35" .01 - 1.2 .06 Pass & Controls AH-2 Air Products SL-2000-P Return 19" 17" .01 - 1.2 .01 Pass & Controls AH-3 Air Products SL-2000-P Return 36" 38" .01 - 1.2 .03 Pass & Controls AH-4 Air Products SL-2000-P Return 36" 38" .01 - 1.2 .01 Pass & Controls AH-5 Air Products SL-2000-P Return 36" 38" .01 - 1.2 .03 Pass & Controls \��S stems 4 e NEAR �N U ,d fa tFiritcoL6 i .. 3129 Exp.12/31/05 0 10443 N. Cave Creek Road • Ste. 207 • Phoenix, Arizona 85020 • (602) 997-8938 • Fax (602) 944. 9Q-t,n;c 5�5� COMMERCIAL Page 1 of 1 • ``) SYSTEMS ANALYSIS AIR CONDITIONING UNIT OSA TEST PROJECT: The Orthopedic Clinic Associates P.C. - Suite 185 ADDRESS: 6320 W. Union Hills Drive, Bldg. B CITY, STATE Glendale, Arizona DATE: 07-06-06 TECHNICIAN: JW MAKE/MODEL# UNIT DESIGN PRELIMINARY FINAL SERIAL# NO. SIZE "K" FPM CFM FPM CFM FPM CFM NOTES Trane /TWE060A400EL AH-1 10"0 .54 370 200 618 334 388 209 545654MBD Trane /2TEC3F36A1000AA AN-2 10"0 .54 185 100 580 313 193 104 54247DEIV Trane / TWE060A400EL AH-3 10"0 .54 370 200 800 432 396 213 5454NH6BD Trane / TWE060A400EL AH-4 10"0 .54 370 200 514 277 382 206 5434L5BBD Trane / TWE060A400EL AH-5 10"0 .54 370 200 791 427 386 208 5454NJCBD Total 900 1783 940 NOTES: is--sterns q/2 Fir---;-- N 0 U , AH 29 Ex .12/31/p % e iailYdronic S�s`