Loading...
HomeMy WebLinkAbout19361 Jun 15 05 07: 51a E T B 602-861 -1864 p. 1 NVIRONNI NTAL ES71NC & 4I.ANCINC, INC. T A I IVA(' I f 1'I INti,AAAI Ytiis. BALANCING, ('t)MMISSII)NINn, . .- fitu:ecr Struvm•s Rc Muir.i Lit t:SAFETY icrY Trs INI; DATE: June 15,2005 JOB: Apex Physical Therapy 6320 W.Union Hills'Rd.Suite 265 - Gicndalc,AZ • FOR: NISI • DUCT DETECTOR CERTIFICATION • UtitTR 1t:1NUF 1t(Y11N1 I1ll(«1 .111w: At" I' 1'Fa.[)('1'19' 'I Itr`.,�1'Tx1IM1 ---I'A+IF7, PASS SIZE t.r:n[:nt Ul' (11'M) 111)I.r:% rl\rF; INI►1('.1'I'li)N / I.IM:1'1'll)N . PIM)IW FAIL AI'-01 Ihltlix • 2GSUGbU 1RX2U 1G" R. I.Ofi 971 lt} IM 1hDlAI1t Slllltltvliiu kV Irn1s cat-02 HRH x ZGSU GGU 2U x 20 16" It I.07 98X 10 IMMIi IATsa SImIiRvlu,rcv rANN Visual inspection: Environmental Testing&Balancing„Inc. , • Certifies to the best of their knowledge,the above smoke detectors have been indallet as close as possible in accordance to the manufacturer's recommendation and as indicated on the drawings. Due to the slight flw to%lions in the pressure readings,the above data refuels the lowest reading's measured to assure compliance. The pressure in the sampling tube must be greater Than.0015"nP and not greater than 1.2'1)1'. EIartwlralInspection: Tested and compliek Functional Torsi: Automatic ihototT verification completed.All units shut of immcdiately when either smoke detector wax activated by smoke in a can. Any future adjustment%to any units air now would afTed the functional test and the detector:would subsequently nixed to be retested. General(nturmsl)nn; • The operation of the smoke detector may be impeded i 1-the fans and the units are not properly serviced (Hell tension,Filters,Dampers). This can and will change the airflow al the detectors,which could reduce the velocities required by the manufacturer. This wskd[I elrsxl the ability of the detectors to:knee smoke. it is the responsibility of the owner/user for the ongoing maintenance ant testing as indicatal in the installation instructions_ Tato/Bp: Thanun Strn'gri •lillI(.'(:edlfrerl ii.i'' ' : iit . ., ,.. • ,..k\ti,"j4aitt_ at1�yi • ��J,j / • • ` C� �a>� ,...., AIC l' 321 W.I iatchset'.Suite 202 • i'hoenix.AZ S502 I • (602)861-145N • Fax;(h(1?1 Sb I-I S64 • www.elltarizoritt.com Jun 15 05 07: 52a E T B 602-861-1864 p. 2 NVIRONMENTAL ESTING & ALANCING, INC, IIVAC I'I:ti-1'IN(3.AAA!VMS. RAI ANI'I1.11:,(•OMMISNRININI,, fent¢uc v tiutevrvti IZ Flkr:l.irr S.urIrrt•Ttsrtnr; June 15, 2005 Environmental Testing& Balancing,'inc. Certifies these flows are as follows OUTSIDE AIR CERTIFICATION APEX PHYSICAL THERAPY UNIT REQUIRED FINAL PASS AC-01 4(X) • 420 PASS AC-02 300. 315 PASS ,h,o, • ACCX solk 32t W.I late:hler,Suite 21)2 • Phoenix,AZ S502I - (602)146I-I45X • Fax:((i)2)X61-1 X4 4 • www.etharizona-rom