Loading...
HomeMy WebLinkAbout164849 CITY OF GLENDALE PLANNING&DEVELOPMENT SERVICES JOB SITE COPY 5850 W.GLENDALE AVE.,2ND FLOORTHESEBSITE PLANS SHALL A ILA BE KEPT BLETO AT CI THE JOTY GLENDALE,AZ 85301 OF GLENDALE INSPECTORS DURING SPECIAL INSPECTION CERTIFICATE Glendale 623.930.2800 WORKING HOURS. PLANS SHALL NOT ARIZONAWITHOUT www.GlendaleAZ.com BE ALTERED OFFICIALS A PROVAL.DING STRUCTURAL OWNER'S NOTIFICATION OF SPECIAL INSPECTION To be completed and signed by the Owner before a building permit is issued In accordance with Sections 1704 and 1705 of the 2018 International Building Code which requires that certain construction work be placed under inspection of a registered design professional.I,as owner/legal agent,do hereby certify that I have retained Caruso Turley Scott to be responsible for the special inspections on this project. (Registered Design Professional/Firm-please print) Owner's name: Monty Coury Owner's Signature: Monty Coury Date: 1 1/03/2023 PROJECT NAME: REGISTERED DESIGN PROFESSIONAL/FIRM NAME: 1 Brady Notbohm/Caruso Turley Scott 6760 Deer Valley TIA PROJECT ADDRESS: REGISTERED DESIGN PROFESSIONAL/FIRM ADDRESS: C67.60-Deer-Vali Rp Brady Notbohm/ GLENDALE;AZ 85310 1215 W.Rio Salado Pkwy.,Suite 200 Tempe,AZ 85281 ce0G.PROJECT NUMBER _ —23255.52 3 EdOG_FERMIT'NUMBER: 164849 7 CERTIFICATE OF RESPONSIBILITY CERTIFICATE OF COMPLIANCE To be filled in and signed by the professional in charge of Special Inspections To be filled in and signed by the professional in charge of Special Inspections before a building permit is issued. before a certificate of occupancy is issued. As registered design professional in tonal I certify that,to the best of my charge of special inspections of the o�e� 6�9/ knowledge,the requirements of the o�esstonal 9/ above named project,I certify that I Q� q�F►�ATEA`r 2018 International Building Code Qc _of1CATF am familiar with the design of the �� V� °p f� and the approved plans and 4. V� 6 S• � project and hereby assume full .°1 42194 • a specifications have been complied .m 42194 o responsibility for carrying out the �' BRADY K. m with,insofar as the portion of the •�' BRADY K. required special inspections in NOTBOHMill work requiring special inspection NOTBOHM p 10/30/2023 p 02/13/2024 .' accordance with Sections 1704 and �, under Section 1704 and 1705 is d 1705 of the 2018 International 1`;.nea' 4 concerned.A guarantee that the `�``,nea A, Building Code. contractor necessarily constructed Z • the building in full accordance with ' the plans and specifications is neither intended nor implied. (Seal,Signature,and Date) eal,Signature,and Date) SPECIAL INSPECTOR QUALIFICATIONS APPROVAL BY BUILDING OFFICIAL/PLANS EXAMINER(1704.2.1): LA k DATE: 11/16/23 WORK WHICH REQUIRES SPECIAL INSPECTION QUALIFIED SPECIAL INSPECTOR INDIVIDUAL OR FIRM ® CONCRETE CONSTRUCTION/REINFORCING STEEL/POST-TENSION(1705.3) Roger Fraley ❑ MASONRY CONSTRUCTION(1705.4) ❑ WOOD CONSTRUCTION(1705.5) ® STEEL CONSTRUCTION(1705.2&AISC 360) Roger Fraley ❑ SOILS(1705.6) ❑ FOUNDATIONS(1705.7,1705.8&1705.9) • SPECIAL CASES:POST-INSTALLED(EPDXY/EXPANSION)ANCHORS(1705.1.1) Roger Fraley ❑ SEISMIC RESISTANCE(1705.12) ❑ SPRAYED FIRE-RESISTANT MATERIALS(1705.14) ❑ EXTERIOR INSULATION AND FINISH SYSTEMS(EIFS)(1705.16) ❑ STORAGE RACKS(1705.12.7) ��/ FE ❑ OTHER: v be /���• o ii0 Pa FORM EFFECTIVE 04/26/2019 POST AT JOB SITE WITH PERMIT • YOUR STRUCTURAL ENGINEERING EXPERTS • SPECIAL INSPECTION DAILY REPORT MASONRY CARUSO 1215 W.Rio Salado Pkwy. PAGE 1 OF 1 Suite 200 TURLEY Tempe,AZ 85281 DATE TIME JOB WC SCOTT T:(480)774-1700 02-08-24 12:00 pm No. 23-1208S 50 consulting F:(480)774-1701 PROJECT _ structural engineers' Sierra Verde Center T TO: FINN Architects, LLC �cocATIO -- 6Z6O WJJeer_k-alley Rd CITY Glendale 1810 West Loamann Drive CONTRACTOR PM Management INSPECTOR Roger Fraley Queen Creek, AZ 85142 PROJECT ENGINEER JEV ATTN: PRESENT AT silt Richard w/PM Management CC: City of Glendale, File ® Size,Spacing,and Grade of Vertical Reinforcing Steel ® Open-Ended Lintel Block ® Size,Spacing,and Grade of Horizontal Reinforcing Steel ® Rebar Lap Lengths including Joint Reinforcing,Lintels,and Bond Beams ® Cleanliness&Dimensions of Masonry Units El Size and Spacing of Horizontal Joint Reinforcing ® Grout Time in Mixer spec mix,mixed&placed within 20 mins ® Placement of Reinforcing Steel Including Required ® Water Added to Grout? ❑ No ® Yes per spec mix El Clearances and Support 0 Grout Sampled for Strength: ® Dimensions(Depth and Thickness)of Masonry Elements Name of Testing Company ❑ Placement,Size,and Anchors on Embed Plates ® Mix Design#and Grout Strength spec mix,2000 psi El Location of Control Joints ® Grout Vibrated,#Vibrators on Site one ❑ Size,Embedment,and Spacing of Anchor Bolts ❑ Veneer Tie Spacing and Connection ® Size,Length,Spacing,and Placement of Dowels LOCATION'S -. COMMENTS. REFERENCED DETAILS 1st floor level along (1) Inspected on-site mixing, hand-placement&consolidation of GSN, north side of existing - approximately 1 yard of 2,000-psi ArrieriNiix AMX 60U CG notes, building coarse spec-mix grout at remaining CMU wall infill areas for S1.1, voided cells. ` 01, a. Grout was batched on-site per manufacturer's 05 specifications for spec mix. b. Grout conforms to ASTM C476 &ACI 530. c. Grout was hand placed in multiple lifts not exceeding 4'-0"each. (2) Inspected placement of+/-1 1/2"of 5000 psi non-shrink dry pack at steel beam lintels at new openings in existing CMU walls per Details 01 &05. a. No exceptionswers noted._ _-_ _._________ L(_3)Allitems_inspected-appeared-to-be-in-gener-al-confor-mance-with- : 1structUral plans&"details.— j Signed: Roger 1ratey Project Engineer: Inspector Work Codes:50=Typical,51=Reinspection,52=Repairs,53=Late Concrete/Grout,54=Cancelled,55=Sat/Sun/Holiday