Loading...
HomeMy WebLinkAbout160479 JOB SITE COPY THESE PLANS SHALL BE KEPT AT THE . JOBSITE AND BE AVAILABLE TO CITY CITY OF GLENDALE OF GLENDALE INSPECTORS DURING C4PLANNING&DEVELOPMENT SERVICES WORKING HOURS. PLANS SHALL NOT 5850 W.GLENDALE AVE,2ND FLOOR BE ALTERED WITHOUT BUILDINGOFFICIALS APPROVAL. • 623.930.2800 LENDALE,AZ 85301 Glendale 623.930.2800 SPECIAL INSPECTION CERTIFICATE ARIZONA www.GlendateAZcom STRUCTURAL 3-5-2 y OWNER'S NOTIFICATION OF SPECIAL INSPECTION To be completed and signed by the Owner before a building permit is issued In accordance with Sections 1704 and 1705 of the 2018 International Building Code which requires that certain construction work be placed under inspection of a registered design professional.I,as owner/legal agent,do hereby certify that I have retained Robert N.Pocano P.E.I PTI to be responsible for the special inspections on this project. L (Registered DesignProfessional/Firm-please print) Owner's name: Elizabeth Pietrack for Taylor Morrison Owner's Signature:l ?C� i"GL .c2 Date: 2/25/22 yf/ PROJECT NAME: Allen Ranches Plan 5090 REGI ERE)DESIGN PROFESSIONAL/FIRM NAME: Robert N. Pocano P.E./Phoenix Testing&Inspections LLC PROJECT ADDRESS: Standard Plan N/A REGISTERED DESIGN PROFESSIONAL/FIRM ADDRESS: 17817 W Colter St lot 48 3635 S.43rd Ave Phoenix,AZ 85009 COG PROJECT NUMBER: 220819 COG PERMIT NUMBER: /co 4,79 CERTIFICATE OF RESPONSIBILITY I CERTIFICATE OF COMPLIANCE To be filled In and signed by the professional in charge of Special Inspections To be filled In and signed by the professional in charge of Special Inspections before a building permit is issued. [before a certificate of occupancy is issued. As registered design professional in SesSiOn�I€ I certify that,to the best of my oSeggiOf)a/ charge of special inspections of the iQ 4 knowledge,the requirements of the ( Fib above named project,I certify that I /�%c\f I C fl lF tla 2018 International Building Code et.' \f I C A TF,94,9 am familiar with the design of the ;-%��q- m and the approved plans and { y e project and hereby assume full j v,1 U 36871 0 specifications have been complied : .y 0 3867t O C2. responsibility for carrying out the ROBERT N. -4 with,insofar as the portion of the ' ai ROBERT N. required special Inspections in CL POCANO work requiring special inspection O POCANO `� accordance with Sections 1704 and O under Section 1704 and 1705 is / 1705 of the 2018 International ��asr fled'' concerned.A guarantee that the ��1� P`)../fled t%/ BuildingCode. �¢ y S P. contractor building necessarily constructed • 9 ✓ C.fpr ONA u' ., the building in full accordance with J' �-jp/�/ ONA U d r8g� the plans and specifications Is @g neither Intended nor implied. (Seal.Signature,and Date) (Seal.Signature,and Date) SPECIAL INSPECTOR QUALIFICATIONS APPROVAL BY BUILDING OFFICIAL/PLANS EXAMINER(1704.2.1): tk l\ - DATE: 4/29/22 a WORK WHICH REQUIRES SPECIAL INSPECTION QUALIFIED SPECIAL INSPECTOR INDIVIDUAL OR FIRM ®CONCRETE CONSTRUCTION/REINFORCING STEEL(1705.3)PT Slab Const PTI ❑MASONRY CONSTRUCTION(1705.4) ❑ WOOD CONSTRUCTION(1705.5) ❑ STEEL CONSTRUCTION(1705.2&AISC 360) j SOILS(1705.6) PTI ❑FOUNDATIONS(1705.7,1705.8&1705.9) Igl SPECIAL CASES:POST-INSTALLED(EPDXY/EXPANSION)ANCHORS(1705.1.1) PTI ❑ SEISMIC RESISTANCE(1705.12) ❑ SPRAYED FIRE-RESISTANT MATERIALS(1705.14) i .. ❑ EXTERIOR INSULATION AND FINISH SYSTEMS(EIFS)(1705.16) _/,fib ❑ STORAGE RACKS(1705.12.7) �.• 0 OTHER: mar _ FORM EFFECTIVE 04/28/2019 POST AT JOB SITE WITH PERMIT CITY OF GLENDALE PLANNING&DEVELOPMENT SERVICES 5850 W.GLENDALE AVE.,2ND FLOOR GLENDALE,Az85301 Glendale 623.930.2800 SPECIAL INSPECTION/VERIFICATION CERTIFICATE .930.2 www.GlendaleAZcom ARCHITECTURAL ENERGY CODE COMPLIANCE • OWNER'S NOTIFICATION OF SPECIAL INSPECTION To be completed and signed by the Owner before a building permit is issued In accordance with the Glendale City Code,Chapter 9,I,as owner/legal agent,do hereby certify that the construction of the below described building project will receive Special Inspection or Third Party Verification for compliance with the City of Glendale's current adopted Energy Code. The Architect may also certify this project for Energy Code compliance. L �/ Owner's name: Elizabeth Pietrack for Taylor Morrison Owner's Signature: Aditieze4 Date: 2/25/22 PROJECT NAME: Allen Ranches Plan 5090 REGIStrgRED DESIGN PROFESSIONAL/FIRM NAME: Energy Inspectors PROJECT ADDRESS: N/A Standard Plan REGISTERED DESIGN PROFESSIONAL/FIRM ADDRESS: 17817 W Colter St lot 48 2570 S.Miller Lane Las Vegas,NV 89117 COG PROJECT NUMBER: 220819 COG PERMIT NUMBER: SPECIAL INSPECTION/VERIFICATION RESPONSIBILITY CERTIFICATE CERTIFICATE OF COMPLIANCE&APPLICATION FOR CERTIFICATE OF OCCUPANCY To be filled in and signed by the Architect,Special Inspector,Contractor or Third To be filled in and signed by the Architect,Special Inspector,Contractor or Third Party Responsible for verification. Party Responsible for verification. I certify that I am familiar with the The construction of the above energy code compliance named project is complete and requirements of the above named meets or exceeds the requirements project and energy conservation.I of the City of Glendale's currently hereby assume full responsibility to adopted Energy Code.Request is carrying out the required special hereby made for issuance of the inspections and verifications. certificate t, the best. I certify that,to the best of my knowledge,the requirements of the �3.2.2022 approved plans for which Special1061t( Inspection or Third Party Verification is required have been met. (Architect's Seal,Signature,and Date-If (Architect's Seal,Signature,and Date-If applicable) applicable) SPECIAL INSPECTOR QUALIFICATIONS APPROVAL BY BUILDING OFFICIAL/PLANS EXAMINER:_ DATE:3/29/2022 Instruction/Information about this form: 1. A Special Inspection is not"Required". 2. The person signing in the area that states that project will conform to the currently adopted Energy Code does not have to be the same person that verifies those requirements. 3. The City of Glendale,Arizona,only needs this form completed and returned;we do not need any supporting documentation in order to issue a Certificate of Occupancy. JOB SITE COPY THESE PLANS SHALL BE KEPT AT THE JOBSITE AND BE AVAILABLE TO CITY OF GLENDALE INSPECTORS DURING WORKING HOURS. PLANS SHALL NOT BE ALTERED WITHOUT BUILDING OFFICIALS APPROVAL. 44) FORM EFFECTIVE 04/26/2019 POST AT JOB SITE WITH PERMIT •••• •• pT • • Phoenix Testing & Inspection LLC 3635 S.43rd Avenue• Phoenix,AZ.85009•Phone(602)272-2688• Fax(602)272-0804 Drainage Inspection Inspection Date 1- 13 - Lq Inspector JQOSe i jixjyr, Community 41/4i itaKe4 (7)-pAI(t fpr , Address 1107 C.i CQI/'v If Lot# Ile Builder 1-C44 j[or/ ,lcNi-'r 4 del Model&Elevation Permit B iLoti 7e Concrete Contractor Notes Grading Contractor Structural Engineer Lot Landscaped YES ❑ NO Home Occupied YES ❑ NO JA Diagram (v3-U$ 1 fJ Z.3 Q, I COO 102.4.$ ------ - (c,LAt/ t,033 s-fb '3 ! 0100 Ick 15,1 )e1.-2 tot) 0 ' • - r l 20 S �� ("1";li 1,01. 05 -v1r3 ( oo. c 41 / I Obi Co ( c.io 6 4 Comments Drainage Inspection Results (please circle one of the following) eats B der Does Not Meet Require ants Builder Requirements Updated ovrrroa IARCX1S Inspection Summary 17817 W Colter St Litchfield Park, AZ 85340 1 IC - Pass Scheduled Date Completed Date I 2/19/2024 2/19/2024 Casey Weber Builder Inspector Phone cu Taylor Morrison AZ 602-616-8812 z Community Lot Plan Sq Ft. _ Allen Ranches Expeditio 4048 G50205 0 l Superintendent Superintendent PO# ai - �" Paul O'Brien Not Assigned 48204200_000538 > , Superintendent Attended Inspection Number Volume Volume w!Attic 2 i• 1` No 1 0.00 0.00 `'*, _ ..x Blower Door =sta'.• ;SPT ACH50 MPT ACH50 Pass ; 0 3.06 Duct Blaster 1 Kt" I TDLY, LTD 0 Pass i 0 Duct Blaster 2 TDL% _*o% 0 Duct Blaster 3 TDV; LTO% 0 Insulation Verification iP 7., -p„- __.. ` Lighting Components Pass - " 't - i Ventilation Testing System Delivery Unanswered Mechanical Exhaust iPass -} " ' {kls A4 }t j Static Pressure Unanswered Room Pressure lPass� i-'°'" �� ;7 _ i't;� VERSION 3.1 REFERENCE:1728447