Loading...
HomeMy WebLinkAbout00000 (5) i f � o, ^r t'J ll- i- - ; ' ' — '' Project: Little Caesars 10240 N. 43rd Ave. Glendale, Arizona i'l:;'''''''''''''':.4 - MAP Job # 10-1846 i �4 ez :,4,1yr r `rr S�# rt Py'M TES TANDALBAANCE i';'''''' v Architect: ArizaDo Architecture 6910 E. Chauncey Ln., Suite 105 Phoenix, Arizona 1 641 N. Ha11 1VIesa, 'AZ 85203 ' Engineer: ArizaDo Architecture 6910 E. Chauncey Ln., Suite 105 Phoenix, Arizona k d k 1 [- , t L ` I➢' Mechanical Contractor: L&H Mechanical Cell (480)69576314, 4038 E. Superior Ave. Fax:(480)287=9673 Bldg. #2 Suite 103 Email:.thebest:@rnaptab cdm t. Phoenix, Arizona A CERTIFICATION PROJECT: Little Caesars ADDRESS: 10240 N. 43rd Ave. Glendale, Arizona THE DATA PRESENTED IN THIS REPORT IS A RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH ASHRAE STANDARD 111-2008 FOR MEASUREMENT, TESTING, ADJUSTING, BALANCING OF BUILIDING HVAC SYSTEMS . THE AIR VELOCITY IN THE INSTALLED 18 x 18 DUCTWORK IS 693 WHICH MEETS OR EXCEDES DESIGN PARAMETERS. THE AIR AND/OR WATER DISTRIBUTION SYSTEMS HAVE BEEN TESTED, BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH ASHRAE STANDARD 111-2008 FOR MEASUREMENT, TESTING, ADJUSTING, BALANCING OF BUILIDING HVAC SYSTEMS AND THE PROJECT SPECIFICATIONS SUBMITTED & CERTIFIED BY: Michael R. Gifford �PQ.cssi&BALL Ce ed11)01P 0 C'Sae1 � 1 , . , . . . ..,...,,, ... ,,,, , . ID; . „.. .....„,. ,-,-„ , „ ..,., , „. n. h ;yA PROJECT: Little Caesars UNIT NUMBER: RTU-1 LOCATION: M-1 UNIT DATA MOTOR DATA Manufacturer Trane Make/Frame GE / 56 Model Number WSC090A3RoAoF HP/RPM 1 / 1725 Serial Number 225100863L Volts/Phase 208-230/460 / 3 Fan Sheave Make Browning F.L. Amps/S.F. 3.2-4.0/2.0 / 1.15 Fan Sheave Diam./Bore AK59 x 1" Make Sheave Browning No. Belts/Size 1 / A32 Sheave Diam./Bore 1VL40 x 5/8" # Filters/Size 4 / 16" x 25" x 2" TEST DATA TEST DATA EVAPORATOR DESIGN ACTUAL CONDENSER DESIGN ACTUAL Total CFM 2,000 2,175 Compressor Volts 208-230 210 External Static Pressure 0.50" 0.53" Compressor Amps 26.0 22.8 Discharge S.P. inches W.C. --- 0.36" Condenser Fan HP 7/10 7/10 Suction S.P. inches W.C. --- -0.17" Condenser Fan Volts 208-230 210 Return Air CFM 1775 1,946 Condenser Fan Amps. 2.90 2.37 Outside Air CFM 225 229 Condenser Fan RPM 1100 DD Entering Air Temperature --- 76°F Leaving Air Temperature --- 56°F Fan RPM --- 1072 *For all other refrigeration, compressor, and Voltage 208 210 condenser test data see start-up report from Amperage 3.20. 2.96 the installing contractor and/or supplier Notes: Test Date: April 5, 2010 Tech: M.R. Gifford 101846-Little Caesars @ Glendale Page 1 , 4 t x"C 4 AIR OUTLET/INLET TEST REPORT PROJECT: Little Caesars UNIT NUMBER: RTU-1 LOCATION: 'M-1 OUTLET DESIGN PREM. FINAL PERCENT AREA SERVED NOTES NO. TYPE SIZE CFM CFM CFM OF DESIGN Lobby 100 1 CD 24" x 24" 400 602 441 110% Lobby 100 2 CD 24" x 24" 400 541 437 109% Lobby 100 3 CD 24" x 24" 400 569 433 108% Lobby 100 4 CD 24" x 24" 400 419 436 109% Lobby 100 5 CD 24" x 24" 400 374 428 107% 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 TOTAL 2,000 2,505 2,175 NOTES: Test Date: April 5, 2010 Tech: M.R. Gifford 101846-Little Caesars @ Glendale Page 2 aim-J.. �.�;. - .t11'G7/—�,`C{ ' Sys 4 :, {S + i •• 'a.. 7 cgu PROJECT: Little Caesars UNIT NUMBER: RTU-2 LOCATION: M-1 UNIT DATA MOTOR DATA Manufacturer Rheem Make/Frame (1) Model Number RKNL-A060L10E HP/RPM 3/4 / 1725 Serial Number 2G7503ADAAF Volts/Phase 208-230/460 / 3 Fan Sheave Make Browning F.L. Amps/S.F. 3.4/2.7 / 1.15 Fan Sheave Diam./Bore AK66 x 3/4" Make Sheave Browning No. Belts/Size 1 / A42 Sheave Diam./Bore 4" O.D. x 5/8" # Filters/Size 2 / 16" x 25" x 2" TEST DATA TEST DATA EVAPORATOR DESIGN ACTUAL CONDENSER DESIGN ACTUAL Total CFM 2,000 1,858 Compressor Volts 208-230 210 External Static Pressure 0.50" 0.53" Compressor Amps 15.6 14.3 Discharge S.P. inches W.C. --- 0.32" Condenser Fan HP 1/3 1/3 Suction S.P. inches W.C. --- -0.21" Condenser Fan Volts 208-230 210 Return Air CFM 1775 1,624 Condenser Fan Amps. 1.80 1.46 Outside Air CFM 225 234 Condenser Fan RPM 1075 DD Entering Air Temperature --- 77°F Leaving Air Temperature --- 56°F Fan RPM --- 948 *For all other refrigeration, compressor, and Voltage 208 210 condenser test data see start-up report from Amperage 3.40 3.17 the installing contractor and/or supplier Notes: (1) Nameplate is not visible. Test Date: April 5, 2010 Tech: M.R. Gifford 101846-Little Caesars @ Glendale Page 3 mil Cr y. A. #..#7.. #1' r k, n. Ik� ' ydf,�, AIR OUTLET/INLET TEST REPORT PROJECT: Little Caesars UNIT NUMBER: RTU-2 LOCATION: M-1 OUTLET DESIGN PREM. FINAL PERCENT I AREA SERVED NOTES NO. TYPE SIZE CFM CFM CFM OF DESIGN Backroom 102 1 CD 24" x 24" 400 374 374 94% Backroom 102 2 CD 24" x 24" 400 392 392 98% Backroom 102 3 CD 24" x 24" 400 368 368 92% Backroom 102 4 CD 24" x 24" 400 360 360 90% Backroom 102 5 CD 24" x 24" 300 273 273 91% Restroom 103 6 CD 12" x 12" 100 91 91 91% 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 TOTAL 2,000 1,858 1,858 NOTES: Test Date: April 5, 2010 Tech: M.R. Gifford 101846-Little Caesars @ Glendale Page 4 may, .0y xis {{{"��� yet 1 r ` ,R.,�� {{{'4 orb , 4 - , w: ,A, ,.. ,Ii r *41 6 Toilet Exhaust Fans PROJECT: Little Caesars EF-1 Location Ceiling Service Restroom 103 Design CFM 100 Actual CFM 108 NOTES: Test Date: April 5, 2010 Tech: M.R. Gifford 101846-Little Caesars @ Glendale Page 5 C '°.tip..: Fan PROJECT: Little Caesars FAN DATA EF-2 MAU-1 Location Roof Roof Service Kitchen Hood Kitchen Hood Manufacturer Accurex Aaon Model Number XRUB-141-5-6 RMA-05-8-0-BB01 Serial Number 11927358 0912 200908-AMCE07174 Motor Make/Frame Marathon / 48Y Marathon / 56HZ-70 Motor HP / Phase / RPM 1/2 / 1 / 1725 1 / 3 / 1725 Volts/Amps 115 / 7.5 208-230/460 / 3.5-3.6/1.8 Motor Sheave Make Browning Browning Motor Sheave Diam./Bore 1VP34S x 1/2" 1VP44 x 7/8" Fan Sheave Make Browning Browning Fan Sheave Diam./Bore AK46 x 3/4" BK62 x 1" No. Belts/Size 1 / AP20 1 / BX48 FAN TEST DATA DESIGN ACTUAL DESIGN ACTUAL CFM 1380 1472 1380 1329 ' Fan RPM --- 1054 856 1011 External S.P. --- .53" 0.75" 0.69" MOTOR TEST DATA VOLTAGE AMPS VOLTAGE AMPS T-1/T-2 117 7.26 210 i 3.21 T-2/T-3 T-1/T-3 NOTES: Area Velocity Design Actual 1.25 747 Prep 101 480 471 Area Velocity Prep 101 450 436 1.25 725 Prep 101 450 422 Test Date: April 5, 2010 Tech: M.R. Gifford 101846-Little Caesars @ Glendale Page 6 f,,i y+.. AIR BALANCE SCHEDULE PROJECT: Little Caesars UNIT SERVED LOCATION DESIGN ACTUAL DESIGN ACTUAL PERCENT EF CFM EF CFM OSA CFM OSA CFM OF DESIGN EF-1 1 Roof 100 108 108% EF-2 2 Roof 1380 1472 107% 3 TOTAL 1480 1580 MUA-1 1 Roof 1380 1329 96% RTU-1 2 Roof 225 229 102% RTU-2 3 Roof 225 234 104% TOTAL 1830 1792 Test Date: April 5, 2010 Tech: M.R. Gifford Page Caesars @ Glendale gge 7 N., fir ..,,, 5, Ak ' 4kr Duct Smoke Detector Test Report {{{{{f..;..:Li," 111.-t.:,:;4.14.. .":_;-. -,,,\:Tn:,;,..,14.5.; PROJECT: Little Caesars LOCATION: 10240 N. 43rd Ave. Glendale, Arizona SMOKE DETECTOR VELOCITY FPM DIFFERENTIAL PRESSURE SAMPLE FIRE PANEL SMOKE FAN NO. INCHES W.C. TUBE ADDRESS/ TEST SHUT PASS FAIL NOTES LENGTH ZONE OFF TIME MANUFACTURER MODEL NUMBER LISTED ACTUAL LISTED ACTUAL RTU-1 Air Products SL-2000-N 100-4000 358 .01 to 1.2 0.09 PASS Supv. Only 0 Seconds X RTU-2 Air Products SL-2000-N 100-4000 312 .01 to 1.2 0.11 PASS Supv. Only 0 Seconds X NOTES: * All duct smoke detectors were tested with aerosol smoke, which met the manufacturer's requirements. The design data was acquired from the information listed in the manufacturer's "submittal" which was on site at the time the tests were performed. Installation of the duct detectors, T&g wiring to fire panel ( if applicable), and all other manufacturer's installation requirements have been „79,__� A •,Y�•,, met. Each duct detector has an audio/visual remote device which signals when the individual11 duct detector goes into alarm. f 1 * / Certifies } / i �r'�Da '` .c �o, haei�G�. MAP Test and Balance, LLC Technician: M.R. Gifford 641 N. Hall, Mesa, AZ 85203 Test Date: April 5, 2010 Page 1- 101846-Little Caesars @ Glendale , . ._ , . , . . . T rio, k . 1, , - t N .:. ...„.., ...,,,, Fa 1 T I Att, , ;„. L DATE: 30 December 2009 IH TO: Frontera Building Cornpan ,LLC 4110 N. Scottsdale Road ... Suite 125 Scottsdale,AZ 85251 Attn: Ben Irwin FROM: Chris Cooper A LA RE: Little Caesars 10240 N 43rd Avenue Glendale, Arizona 85302 CC: File Ben, Please accept this letter as written acceptance for the use of'underground type I.'piping. Construction will need to be in conformance with all apol:cable codes and requirements If you should Rate any questions or comments please call me Thank you ) Id , icooPER 4 '1.. \,Z.,--i•41-':: Arizapo f,i1111z,gl 1:117,kvinv iiifT Si, 05 Piwenly Prfr'ina 4iii?7E8?Mil p"430 7.58 MI5 f Ment2r I C C •liff,A. -IESC -4.1:,