Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
31284
0-40 COMMERCIAL SYSTEMS ANALYSIS R.O.C.#099027 H.V.A.C. Independent Testing & Balancing Air • Water • Sound • Vibration Active member of the National Environmental Balancing Bureau (NEBB) Certification No. 3129-09 I TEST AND BALANCE ANALYSIS REPORT The Vitamin Shoppe - Suite 150 @ The Shops at Arrowhead 7708 W. Bell Road Glendale, Arizona DATE: 01 -25-07 ARCHITECT: DFD Cornoyer Hedrick MECHANICAL ENGINEER: Mechanical Design, Inc. WORK CONTRACTED BY: Tri-Mega Mechanical SUBMITTED AND CERTIFIED BY: COMMERCIAL SYSTEMS ANALYSIS, INC. ARIZONA LIC. #099027 10443 N. Cave Creek Rd., Suite 207 PHOENIX, ARIZONA 85020 (602) 997-8938 NEBB Reg. No. 3129-09 Qualified Supervisor - Kurt Michael Wahl 10443 N. Cave Creek Road • Ste.207 • Phoenix, Arizona 85020 • (602) 997-8938 • Fax (602) 997-9106 ., ..f, - - _ ■ • a CERTIFIED TEST , ADJUST , AND BALANCE REPORT DATE: 01-25-07 PROJECT: NAME: The Vitamin Shoppe - Suite 150 C� The Shops at Arrowhead ADDRESS: 7708 W. Bell Road Glendale, Arizona ARCHITECT: NAME: DFD Cornoyer Hedrick ADDRESS: 2425 E. Camelback Rd. - Suite 400 Phoenix, Arizona 85016 PHONE: (602) 381-4848 FAX: (602) 381-4844 DESIGN ENGINEER: NAME: Mechanical Design, Inc. ADDRESS: 7227 N. 16TH Street - Suite 200 Phoenix, Arizona 85020 PHONE: (602) 943-6608 FAX: (602) 943-6181 HVAC CONTRACTOR: NAME: Tri-Mega Mechanical ADDRESS: 4830 North 92nd Lane Phoenix, Arizona 85037 PHONE: (602) 795-2499 FAX: (602) 973-4059 NEBB TAB FIRM: NAME: Commercial Systems Analysis, Inc. ADDRESS: 10443 N. Cave Creek Rd., Suite 207 Phoenix, AZ 85020 PHONE: (623) 695-3088 FAX: (623) 322-8777 TAB CERTIFICATION NUMBER: 3123-09 National Environmental Balancing Bureau NLTiB la ® Certification Project: The Vitamin Shoppe - Suite 150 @ The Shops at Arrowhead 7708 W. Bell Road Glendale, Arizona The data presented in this report is an exact record of system performance and was obtained in accordance with NEBB standard procedures. Any variances from design quantities that exceed NEBB tolerances are noted throughout this report. The air distribution systems have been tested & balancing and final adjustments have been made in accordance with NEBB "Procedural Standards for Testing, Adjusting and Balancing of Environmental Systems" and the project specifications. NEBB TAB FIRM Commercial Systems Analysis, Inc. Reg. No. 3129 Certified by Kurt M. Wahl Date: 01-27-07 Submitted & Certified by: NEBB TAB FIRM Commercial Systems Analysis, Inc. TAB SUPERVISOR Kurt M. Wahl /,1,, Reg. No. 3129 Signature /� / 4 \a�s stems q EE' BB t) O 0 KURT M.WAHL CERTIFICATION 3129 ExP• 12/31/07 'Ydronic trIT COMMERCIAL 1,:i. I itsJ eJ SYSTEMS .0 1 ANALYSIS .-,, ,,,,,. 9 Performance Guarantee .v., J For Testing, Adjusting and Balancing Of HVAC Systems For: kir The Vitamin Shoppe - Suite 150 @ 14d The Shops at Arrowhead R 7708 W. Bell Road :l Glendale, Arizona By r Commercial Systems Analysis, Inc. el r :d Commercial Systems Analysis, Inc. (CSA) unequivocally guarantees the Testing, Adjusting and Balancing of the HVAC systems documented in ei r our TAB report, and certifies that the data stated is true, and that we have attempted to optimize to performance of the equipment within the limits of the design and installation, and to meet the design specification as closely as reasonably possible. If after receipt of this report, there are tP 4$,P concerns regarding the validity of the Test and Balance, at the owner's, architect's and/or consulting engineer's request, CSA will conduct ';r t performance testing which may be observed by the owner, architect, engineer and/or authorized representatives. If the result of the testing reveals 4, :► 4 CSA's Testing and Balancing to be deficient*, CSA will conduct all necessary retesting and rebalancing to correct the deficiency at no cost to the o,' r owner. In our effort to continue to surpass industry standards, we guarantee the Testing and Balancing for a period of TWO YEARS from the date ` of the report. .i d �i *CSA cannot be held responsible for problems occurring due to lack of or improper IA'r maintenance including dirty coils and/or filters, improper static pressure control �� fa, �4�r � �" (where applicable), defective and/or uncalibrated thermostats or sensors, equipment � � k1,r or control failure, design deficiencies, load requirement changes or any alterations . k"4 in the air distribution system and/or design thereof. —ft --- a 404 i C ; The data presented in this report is an exact record of the system performance and was obtained in accordance with NEBB Standards Procedures. Any variances from design quantities that exceed NEBB tolerances are noted throughout this report. The air distribution systems have been tested & balanced and final adjustments have been made in accordance with NEBB "Procedural Standard for Testing, Adjusting & Balancing of Environmental Systems" and the project specifications. 4170 The results of these tests are herein recorded. NOTES AND OBSERVATIONS The Vitamin Shoppe - Suite 150 @ The Shops at Arrowhead 7708 W. Bell Road Glendale, Arizona Date: 01-25-07 The test and balance was completed as specifications required. See notes on respective pages as they pertain. Technician: Kent INSTRUMENTATION Equipment Make Model Serial# Cert of Calibration Date Flowhood Shortridge 24x24 top N/A 07-28-06 to 07-28-07 Airdata Multimeter Shortridge ADM-870C M03581 07-28-06 to 07-28-07 Hydrodata Multimeter Shortridge HDM-150 W92045 12-06-06 to 12-06-07 Digital Multi-Voltmeter Fluke 335 88507232 11-03-06 to 11-03-07 Digital Thermometer Fluke 50D 79690086 11-03-06 to 11-03-07 Digital Tachometer Ametec 1726 082793003 11-03-05 to 11-03-07 PROJECT NAME: The Vitamin $hoppe TABLE OF CONTENTS Unit Number Description Location Page AC-1 & AC-2 Existing Packaged Air Conditioning Unit Test M201 1 Air Distribution M201 2 AC-3 & AC-4 Existing Packaged Air Conditioning Unit Test M201 3 Air Distribution M201 4 EF-1 & EF-2 Exhaust Fan Unit Test M201 5 Reduced Plan lof5 0401E7K Page ANALYSIS PACKAGE SYSTEM DX TEST PROJECT: The Vitamin Shoppe SYSTEMS: AC-1 / AC-2 DATE: 01-25-07 LOCATION: M201 TECHNICIAN: KM - MG UNIT # AC-1 AC-2 MANUFACTURER _ Carrier Carrier MODEL# / SERIAL# 50TFQ005 / 4106G30435 50TF0005 / 4406G40446 DESIGN DATA FINAL DATA DESIGN DATA FINAL DATA TOTAL CFM 1600 1610 1600 1625 RETURN CFM / OSA CFM 1350 250 1350 260 1350 j 250 1367 258 FAN STATICS: EXT. /TOTAL .40" .43 " .70 " .40" .46 " .72 " FAN STATICS: IN / OUT - .42 + .28 - .42 + .30 COOLING COIL: IN/ OUT/ DELTA"P" - .20 - .42 .22 - .21 .42 .21 FILTER: IN/ OUT/ DELTA"P" _- .15 - .20 .05 _ - .16 - .21 .05 INDOOR MOTOR: HP / RPM 1/2 1075 1/2 Med Speed 1/2 1075 1/2 Med Speed INDOOR MOTOR:VOLTS/PH/HZ 208 1 60 209 1 60 208 1 60 209 1 60 INDOOR MOTOR: AMPS/ S.F. 3.5 sr 1.0 2.6 3.5 sr,: 1.0 2.7 INDOOR MOTOR: TYPE Direct Drive Direct Drive MOTOR: SPEEDS / SETTING _ 3-Speed , Medium Speed 3-Speed Medium Speed COMPRESSOR: VOLTS/PH/HZ 208 3 60 209 3 60 208 3 60 209 3 60 COMPRESSOR: AMPS 16.8 _ 13.2 12.4 12.6 16.8 12.4 12.2 11.7 CONDENSER FAN:VOLTS/PH/HZ 208 1 60 209 1 60 208 1 60 209 1 60 CONDENSER FAN: AMPS 1.5 1.4 ) 1.5 1.5 TEMPERATURE TEST I I COOLING TEMP.DB IN/ OUT/DELTA "T" 72.0 50.8 21.2 71.4 49.6 21.8 COOLING TEMP.WB SIN/ OUT/ DELTA"T„ 51.6 40.6 11.0 51.2 _ 40.2 11.0 , NOTES: AC-1 OSA: 8.5" x 8.5" = .50 sq ft x 519 FPM = 260 CFM AC-2 OSA: 8.5" x 8.5" = .50 sq ft x 516 FPM = 258 CFM O SYOS EMSRCIAL Page 2 of 5 ANALYSIS AIR DISTRIBUTION TEST PROJECT: The Vitamin Shoppe SYSTEMS: AC-1 / AC-2 DATE: 01-25-07 LOCATION: M201 TECHNICIAN: KM - MG TERMINAL DESIGN TEST-FPM/CFM FINAL ROOM NO. SIZE DIA. "K" FPM CFM TEST 1 TEST 2 FPM I CFM NOTES _ 1 24x24 10" 250 265 260 2 24x24 10" 275 285 280 3 24x24 10" 300 255 290 4 24x24 10" 250 280 245 5 24x24 10" 250 265 250 6 24x24 10" 275 260 285 AC-1 Total 1600 1610 1610 TERMINAL DESIGN TEST-FPM/CFM FINAL ROOM NO. 1 SIZE DIA. "K" FPM I CFM TEST 1 TEST 2 FPM I CI-NI NOTES 1 24x24 10" 250 270 245 2 24x24 10" 250 315 240 3 24x24 10" 275 255 275 4 24x24 10" 275 260 290 5 24x24 10" 275 270 290 6 24x24 10" 275 260 285 AC-2 Total 1600 1630 1625 NOTES: ©19S EMSRCIAL Page 3 of 5 ANALYSIS PACKAGE SYSTEM DX TEST PROJECT: The Vitamin Shoppe SYSTEMS: AC-3 / AC-4 DATE: 01-25-07 LOCATION: M201 TECHNICIAN: KM - MG UNIT # AC-3 AC-4 MANUFACTURER Carrier Carrier MODEL# / SERIAL# 60TF0005 / 4606G20376 50TF0005 / 4606G20377 DESIGN DATA FINAL DATA DESIGN DATA FINAL DATA TOTAL CFM 1600 1550 1600 1570 RETURN CFM / OSA CFM 1350 250 1297 253 1350 250 1310 260 FAN STATICS: EXT. /TOTAL .51 " .78 " .74 " 1.04 " FAN STATICS: IN/ OUT - .43 + .35 - .56 I + .48 COOLING COIL: IN/ OUT/ DELTA"P" - .19 - .43 .24 - .33 - .56 .23 FILTER: IN/ OUT/ DELTA"P" - .16 - .19 .03 - .26 - .33 .07 INDOOR MOTOR: HP/ RPM 1/2 1075 1/2 Med Speed 1/2 1075 1/2 1075 INDOOR MOTOR:VOLTS/PH/HZ 208 1 60 209 1 60 208 1 60 209 1 60 INDOOR MOTOR: AMPS/ S.F. 3.5 si 1.0 2.5 3.5 SF 1.0 3.2 INDOOR MOTOR: TYPE Direct Drive Direct Drive MOTOR: SPEEDS/ SETTING 3-Speed Medium Speed 3-Speed High Speed COMPRESSOR: VOLTS/PH/HZ 208 3 60 209 3 60 208 3 60 209 3 60 COMPRESSOR: AMPS 16.8 12.6 12.3 12.0 16.8 13.0 12.4 12.3 CONDENSER FAN:VOLTS/PH/HZ 208 1 60 209 1 60 208 1 _ 60 209 1 60 CONDENSER FAN: AMPS 1.5 1.4 1.5 1.4 TEMPERATURE TEST COOLING TEMP.DB IN/OUT/DELTA"T" 71.2 50.6 20.6 70.8 49.8 21.0 COOLING TEMP.WB IN/OUT/DELTA"T" 51.3 40.6 10.7 50.9 40.0 10.9 NOTES: AC-3 OSA: 8.5" x 8.5" = .50 sq ft x 506 FPM = 253 CFM AC-4 OSA: 8.5" x 8.5" = .50 sq ft x 521 FPM = 260 CFM OSSYOS EMSRCIAL Page 4 of 5 ANALYSIS AIR DISTRIBUTION TEST PROJECT: The Vitamin Shoppe SYSTEMS: AC-3 / AC-4 DATE: 01-25-07 LOCATION: M201 TECHNICIAN: KM - MG TERMINAL DESIGN TEST-FPM/CFM FINAL ROOM NO. _ SIZE I_ DIA. "K" _ FPM CFM TEST 1 TEST 2 FPM CFM NOTES_ 1 24x24 6" 75 70 _ 80 2 24x24 6" 75 60 70 3 24x24 10" 250 210 240 4 24x24 12" 400 345 385 5 24x24 12" 400 435 385 6 24x24 12" 400 440 390 AC-3 Total 1600 1560 1550 TERMINAL DESIGN TEST-FPM/CFM FINAL ROOM NO. I SIZE DIA. "K" FPM CFM TEST 1 TEST 2 FPM CFM NOTES 1 24x24 12" 525 480 455 515 2 24x24 12" 550 495 465 535 3 24x24 12" 525 430 470 520 AC-4 Total 1600 1405 1390 1570 NOTES: 819S EMSRCIAL Page 5 of 5 ANALYSIS FAN TEST PROJECT: The Vitamin Shoppe SYSTEMS: EF-1 / EF-2 DATE: 01-25-07 LOCATION: M201 TECHNICIAN: KM - MG UNIT # EF-1 EF-2 -1 MANUFACTURER Cook Cook MODEL # Not Shown On Tag Not Shown On Tag DESIGN DATA FINAL DATA DESIGN DATA FINAL DATA TOTAL CFM 100 * 115 100 * 110 FAN STATICS: TOTAL .125" .14" .125" .14" FAN STATICS: IN / OUT - ATM + .14" - ATM + .14" MOTOR MAKE Fasco Fasco MOTOR: HP / RPM 1/100 1500 1/100 Low Speed 1/100 1500 1/100 Low Speed MOTOR: VOLTS / PH / HZ 115 1 60 120 1 60 115 1 60 120 1 , 60 MOTOR: AMPS / SF .76 si 1.0 .4 .76 H . 1.0 .4 MOTOR TYPE Direct Drive Direct Drive MOTOR SPEEDS / SETTING 2-Speed Low Speed 2-Speed Low Speed NOTES: * At minimum airflow; 2-speed, direct drive motor wired to low speed. Apr 12 07 04: 56p Daniel Ramirez (4801 967-0037 p. 1 • • ■ M & P Solutions, I.L.C . Mechanical & Plumbing Solutions, L.L.C. 2223 South Myrtle Ave.. Tempe. Arizona 85282 Tel: (480) 967-3297 Fox: (480) 967-0037 Email: donnnnpsOcox.net April 12, 2007 Whitney Hale Architecture Edge 208 E. Papago Circle 5. Tempe, AZ 85281 RE: Paddy 0' Furniture M&P Solutions, LLC Job. No: 06063 Dear Whitney, It is acceptable to transition from 1" gas line to a 3/4" gas line at the fire place connection. As the engineer of record we accept this change as a code compliant and cost savings alternative, however, we do not assume responsibility for performance or integrity as a result of system changes from drawings. Please feel free to contact me if you have any questions. Sincerely, xavot;ti Daniel Ramirez / Mechanical/Plumbing Design' 4dis' ! d Project: Paddy 0' Furniture 7708 West Bell Rd. Glendale, Arizona MAP Job # 07-681 MAP TEST AND BALANCE Architect: Architecture Edge 208 E. Papago Circle South Tempe, Arizona 641 N. Hall Engineer: M 8s P Solutions Mesa, AZ 85203 2223 South Myrtle Ave. Tempe, Arizona Mechanical Contractor: Desert Comfort Refridgeration Phone: (480) 275-6970 237 South Date St., Suite B Fax: (480) 275-6971 Mesa, Arizona Email: maptab cox.net a AC to CERTIFICATION PROJECT: Paddy 0' Furniture ADDRESS: 7708 West Bell Rd. Glendale, Arizona This report consists of two (2) pages. The cover sheet and this certification are included with this seal. The data presented in this report is a record of system performance and was obtained in accordance with SMACA and/or ASHRAE standards. Any variances from design quantities which exceed tolerances are noted throughout this report. * All duct smoke detectors were tested with aerosol smoke, which met the manufacturer's requirements. The design data was acquired from the information listed in the manufactures "submittal" which was on site at the time the tests were performed. Installation of the duct detectors, wiring to fire panel ( if applicable), and all other manufactures installation requirements have been met. All duct detectors on the showroom floor are interlocked and when any individual duct detector detects smoke all units within the space shut down. SUBMITTED & CERTIFIED BY: Michael R. Gifford •c05�and Ba/a1>c i Ce * rtifi, 31a� 1o7 A\ Date ` ., ,, ii. MA ° ....7,7, °::::44, ii,,,p, OSA TEST REPORT PROJECT: Paddy 0' Furniture LOCATION: 7708 West Bell Rd. Glendale, Arizona UNIT SERVED LOCATION DESIGN PREM. FINAL PERCENT NOTES OSA OSA OSA OF DESIGN HP-1 1 Roof 373 385 385 103% HP-2 2 Roof 373 391 391 105% HP-3 3 Roof 373 375 375 101% HP-4 4 Roof 373 380 380 102% HP-5 5 Roof 373 386 386 103% HP-6 6 Roof 373 402 402 108% HP-7 7 Roof 373 374 374 100% HP-8 8 Roof 114 118 118 104% 9 10 NOTES: MAP Test and Balance, LLC Technician: M.R. Gifford 641 N. Hall, Mesa, AZ 85203 Test Date: March 21, 2007 Page 2 PH: (480) 275-6970 07681-Paddy 0' Furniture OSA & DD