Loading...
HomeMy WebLinkAbout00000000000f i • xti' '',•` ' j I rli,aR r A� Project: Ritual Addictions Tatoo Shop 6766 West Glendale Ave., Suite 135 Glendale, Arizona MAP TEST AND BALANCE MAP Job # 10-1959 Architect: Reigle & Associates 641 N. Hall 12424 N. 32nd Street, Suite 200 Mesa, AZ 85203 Phoenix, Arizona Office: (602) 354-3223 Cell: (480)695-6314 Fax: (480) 287-9673 Email:thebest@maptab.com ..:,. ,,.,. 1 j\'''''...e.' ; .. 1 MAP �t y CERTIFICATION PROJECT: Ritual Addictions Tatoo Shop ADDRESS: 6766 West Glendale Ave., Suite 135 Glendale, Arizona THE DATA PRESENTED IN THIS REPORT IS A RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH ASHRAE STANDARD 111-2008 FOR MEASUREMENT, TESTING, ADJUSTING, BALANCING OF BUILDING HVAC SYSTEMS . ANY VARIANCES FROM DESIGN QUANTITIES WHICH EXCEED TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR AND/OR WATER DISTRIBUTION SYSTEMS HAVE BEEN TESTED, BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH ASHRAE STANDARD 111-2008 FOR MEASUREMENT, TESTING, ADJUSTING, BALANCING OF BUILDING HVAC SYSTEMS AND THE PROJECT SPECIFICATIONS SUBMITTED & CERTIFIED BY: Michael R. Gifford i (• 1 Certifi- : 1 v 'Noel R.G1 ..,„ . c.„ ....... I MAP Ili , i... , ,, . 1 el, Duct Smoke Detector Test Report 4b=i se` : a PROJECT: Ritual Addictions Tatoo Shop LOCATION: 6766 West Glendale Ave., Suite 135 Glendale, Arizona SMOKE DETECTOR VELOCITY FPM DIFFERENTIAL PRESSURE SAMPLE FIRE PANEL SMOKE FAN NO. INCHES W.C. TUBE ADDRESS/ TEST SHUT PASS FAIL NOTES LENGTH ZONE OFF TIME MANUFACTURER MODEL NUMBER LISTED ACTUAL LISTED ACTUAL HP-7 Edwards/EST SIGA-SD 100-4000 295 .005 to 1.2 0.12 PASS Supv. Only Immediate X NOTES: * All duct smoke detectors were tested with aerosol smoke, which met the manufacturer's requirements. The design data was acquired from the information listed in the manufacturer's "submittal" which was on site at the time the tests were performed. Installation of the duct detectors, s,1�ST&Bq� wiring to fire panel ( if applicable), and all other manufacturer's installation requirements have been �pQ . • met. Each duct detector has a visual remote device which signals when the individual duct detector goes into alarm and reports to a third party fire panel. Certifie-• ?)kOh` l �� Date �' ei R.G' - MAP Test and Balance, LLC Technician: M.R. Gifford 641 N. Hall, Mesa, AZ 85203 Test Date: August 16, 2010 Page 1- 101957-Ritual Addictions • .°`ram._.,.r MAP J. , , L A.: 4, i .4 i f"'iJJtHj e.$ k'' PROJECT: Ritual Addictions Tatoo Shop UNIT NUMBER: Existing RTU 7 LOCATION: A1.1 UNIT DATA MOTOR DATA Manufacturer Carrier Make/Frame GE / 56Y Model Number 50HU1006---521 HP/RPM --- / 1725 Serial Number 4108G40406 Volts/Phase 208-230/460 / 3 Fan Sheave Make Fenner F.L. Arnps/S.F. 5.2 / 2.6 / 1.15 Fan Sheave Diam./Bore AFD44 x 5/8" Make Sheave Browning No. Belts/Size 1 / A36 Sheave Diam./Bore 1VL40 x 5/8" # Filters/Size 4 / 16" x 16" x 2" TEST DATA TEST DATA EVAPORATOR DESIGN ACTUAL CONDENSER DESIGN ACTUAL Total CFM 1,995 2,147 Compressor Volts 208-230 211 External Static Pressure 0.50" 0.53" Compressor Amps 17.3 16.0 Discharge S.P. inches W.C. --- 0.35" Condenser Fan HP 1/4 1/4 Suction S.P. inches W.C. --- -0.18" Condenser Fan Volts 208-230 211 Return Air CFM 1495 1,629 Condenser Fan Amps. 1.50 1.28 Outside Air CFM 500 518 Condenser Fan RPM 1100 DD Entering Air Temperature --- 79°F Leaving Air Temperature --- 61°F Fan RPM --- 1129 *For all other refrigeration, compressor, and Voltage 208 211 condenser test data see start-up report from Amperage 5.20 4.80 the installing contractor and/or supplier Notes: Test Date: August 20, 2010 Tech: M.R. Gifford 101957-Ritual Addictions rev 1 Page 1 �.t� cif, r,MAP 4,4: . , 0:.,,,, raft 4 / -..k, 11 AIR OUTLET/INLET TEST REPORT PROJECT: Ritual Addictions Tatoo Shop UNIT NUMBER: Existing RTU 7 LOCATION: A1.1 OUTLET DESIGN PREM. FINAL PERCENT AREA SERVED NOTES NO. TYPE SIZE CFM CFM CFM OF DESIGN Seating Area 1 CD 24" x 24" 240 262 262 109% Seating Area 2 CD 24" x 24" 240 265 265 110% Seating Area 3 CD 24" x 24" 240 260 260 108% Tattoo 1 4 CD 24" x 24" 240 255 255 106% Tattoo 2 5 CD 24" x 24" 240 263 263 110% Tattoo 3 6 CD 24" x 24" 240 251 251 105% Piercing 7 CD 24" x 24" 240 265 265 110% 1 Office 8 CD 24" x 24" 240 244 244 102% Toilet 9 CD 24" x 24" 75 82 82 109% 10 11 12 13 14 15 16 17 18 19 20 21 22 TOTAL 1,995 2,147 2,147 NOTES: Test Date: August 16, 2010 Tech: M.R. Gifford 101957-Ritual Addictions Page 2